Figure 3-9. Zones 1-9 Wiring Connections - Honeywell ADEMCO VISTA-120 Installation And Setup Manual

Partitioned security system with scheduling
Hide thumbs Also See for ADEMCO VISTA-120:
Table of Contents

Advertisement

Red Jumper
ZONE 2 ZONE 3
ZONE 4 ZONE 5
10
11
12
13
14
15
ZONE 1
+
-
+
N.C.
N.C.
N.O.
N.O.
2k EOLR
2k EOLR
+
+
-
Fire
Usage
N.C.
SMOKE
N.O.
N.C.
Burg.
Usage
2k EOLR
N.O.
Zone resistance (Excluding EOLR):
ZONE 1,8: 100 OHMS MAXIMUM
2k EOLR
ALL OTHER ZONES: 300 OHMS MAXIMUM

Figure 3-9. Zones 1-9 Wiring Connections

The maximum zone resistance is 100 ohms for
zones 1 and 8, and 300 ohms for all other
zones (excluding the 2K EOL resistor).
Wiring 2-Wire Smoke Detectors to Zone 1
Zone 1 has the added capability of supporting 2-wire
smoke detectors. This zone provides enough standby
current (2 mA) to power up to sixteen of the smoke
detectors listed on the following page. Each zone
provides only enough alarm current (20 mA) to power
one smoke detector in the alarmed state. When
assigned zone type 9, the second entry of a Security
Code + OFF sequence at a keypad will interrupt power
to this zone to allow detectors to be reset following an
alarm.
1.
Connect 2-wire smoke detectors across zone 1
terminals (10 & 11) as shown below. Observe
proper polarity when connecting the detectors.
2.
If an EOL resistor is presently connected across
zone 1 terminals, remove it. The EOL resistors
must be connected across the loop wires of
each zone at the last detector.
The alarm current provided by zone 1 will
support only one smoke detector in the
alarmed state.
(+)
(-)
Figure 3-10: 2-Wire Smoke Detector Connected to
ZONE 6 ZONE 7
ZONE 8 ZONE 9
16
17
18
19
20
21
22
23
+
-
+
N.C.
N.C.
N.O.
N.O.
2k EOLR
2k EOLR
+
-
+
-
+
GLASS
BREAK
N.C.
N.C.
N.C.
N.O.
N.C.
N.O.
2k EOLR
2k EOLR
Zone response time:
ZONES 1-8: 350mSec-500mSec
ZONE 9: Programmable for
Fast: 10mSec-15mSec
Normal: 350mSec-500mSec
(default response)
2-WIRE
SMOKE DETECTOR
Zone 1
Compatible 2-Wire Smoke Detectors
You may use up to sixteen 2-wire smoke detectors each
on zone listed in the table below.
DETECTOR TYPE
Photoelectric, plug-in head
Photoelectric, direct wire
Photoelectric w/heat sensor, direct wire
Photoelectric w/B401B base
Photoelectric w/heat sensor and B401B
base
Ionisation, plug-in head
Ionisation, direct wire
Photoelectric duct detect. w/DH400 base
Ionisation, plug-in head
Ionisation w/B110LP base
Photoelectric, direct wire
Photoelectric w/heat sensor, direct wire
Photoelectric w/B110LP base
Unsupervised Usage of Zone 1
Zone 1 can also be used for normally closed,
unsupervised devices by doing the following:
1.
Cut the red jumper on the PC board located above
Zone 1.
2.
Connect closed circuit devices in series with
terminals 10 and 11.
Wiring 4-Wire Smoke Detectors to Zones 1-8
When programmed for fire warning usage, all zones can
monitor 4-wire smoke detectors or N.O. fire alarm
initiating devices. You may use as many 4-wire smoke
detectors as can be powered from the panel's auxiliary
power output without exceeding the output's rating.
Auxiliary power to 4-wire smoke detectors is
not automatically reset after an alarm and
therefore must be momentarily interrupted
using either a normally-closed momentary
switch wired in series with one side of the aux.
power to the smokes, or using a 4204 relay as
described below.
Using a 4204 relay allows the detectors to be reset via
the second entry of a Security Code + OFF sequence.
The 4204 relay must be programmed to activate on
Zone Type/System Operation 54 (Fire Zone Reset).
(+)
10
Refer to #93 Menu Mode Programming in the
Programming Guide for more information.
1.
Connect 12 volt power for the detectors from
11
(-)
Auxiliary Power terminals 6 and 7 as follows:
Wire the [+] side of Auxiliary Power (Terminal
6) to the N.C. contact of the 4204 relay.
Wire the Center Arm or Pole of the Relay to
the [+] Power side of the smoke detector.
2.
Connect the [-] side of the smoke detector to [-] Aux.
Power (Terminal 7). Observe proper polarity when
connecting detectors (see Figure 3-11).
NOTE: Power to 4-wire smoke detectors should be
supervised (use a System Sensor A77-716-01 EOL
relay module connected as shown).
Section 3 – Installing the Control
DEVICE MODEL #
System Sensor 2600EC
System Sensor 2400
System Sensor 2400TH
System Sensor 2451
System Sensor 2451TH
System Sensor 1600EC
System Sensor 1400
System Sensor 2451
System Sensor 1451
System Sensor 1151
System Sensor 2100
System Sensor 2100T
System Sensor 2151
3-5