Wiring Burglary, Panic and Smoke Detector Devices to Zones 1-9

The maximum zone resistance is 100 ohms for zones 1 and 8, and 300 ohms for all other zones (excluding the
2K EOL resistor).
U LC
Smoke detector devices have not been evaluated for ULC installations.
To wire burglary and panic devices to zones 1-9, connect sensors/contacts to the hardwire zone terminals (10 through
23). See Figure 3-9. Connect N.C. and N.O. devices as follows:
Connect N.C. devices in series with the high (+) side of the loop. The 2K EOL resistor must be connected in series
with the devices, following the last device.
Connect N.O. devices in parallel (across) the loop. The 2K EOL resistor must be connected across the loop wires
at the last device.
3-8
Handset
26
27
TERMINALS
ON CONTROL

Figure 3-8: Telephone Line Connections

Red Jumper
ZONE 2 ZONE 3
10
11
12
13
14
ZONE 1
+
+
-
N.C.
N.C.
N.O.
N.O.
2k EOLR
2k EOLR
+
-
Fire
Usage
SMOKE
N.C.
Burg.
Usage
N.O.
Zone resistance (Excluding EOLR):
ZONE 1,8: 100 OHMS MAXIMUM
2k EOLR
ALL OTHER ZONES: 300 OHMS MAXIMUM

Figure 3-9: Wiring Connections for Zones 1-8

Incoming
Telco Line
28
29
30
EARTH GROUND
INCOMING TELCO LINE
DIRECT
CONNECT
CORD
TIP
RJ31X
RING
JACK
PLUG
ZONE 4 ZONE 5
ZONE 6 ZONE 7
15
16
17
18
19
20
+
+
-
N.C.
N.C.
N.O.
N.O.
2k EOLR
2k EOLR
+
+
-
N.C.
N.C.
N.O.
N.O.
2k EOLR
2k EOLR
PREMISES
PHONES
ZONE 8 ZONE 9
21
22
23
+
-
+
N.C.
N.C.
N.C.
N.O.
2k EOLR
Zone response time:
ZONES 1-9: 350mSec-500mSec