Intermittent Sensor Suppression
*84
(partition-specific)
Enter 01-15.
Enter 00 for unlimited reports
Enable Dialler Reports for Panics &
*85
Duress (partition-specific)
0 = disable
1 = enable
Report/Log Zone Type 23
*86
0 = disable
1 = enable
Entry Warning (partition-specific)
*87
0 = 3 short beeps
1 = slow continuous beeps
Burglary Alarm Communicator Delay
*88
(partition-specific)
0 = no delay
1 = 16-second delay
Restore Report Timing
*89
0 = instant
1 = after siren timeout
2 = when system is disarmed
Secondary Subscriber Account
*90
Number (partition-specific)
Enter 00-09; B-F (11-15)
Contact ID Reporting in ASCII
1*00
Through Printer Port
0 = printer – no ISDN
1 = ISDN + callout
2 = ISDN only
3 = callout if ISDN failed
ASCII Contact ID Reporting with or
1*01
without ACK
0 = ACK required
1 = ACK not required
ASCII Contact ID Baud Rate
1*02
0 = 1200
1 = 2400
2 = 4800
Bypass Enable for Fire Zones
1*05
0 = disable
1 = enable
Suppress All Keypad Displays When
1*06
System is Armed
0 = disable
1 = enable
FIELD
TITLE and DATA ENTRIES
This option limits the number of messages (alarms or troubles) sent for a
specific channel in an armed period.
This field has four entries as follows: Zone 995, 996, 999, Duress Enable for
each partition that the panics and duress reporting is desired.
If enabled, faults of zone type 23 are communicated and logged in the event
log.
Select the type of warning for the entry delay period.
Select the delay, if any, for burglary alarm communications.
Select the time when restore reports are sent after an alarm.
Enter a 3- or 4-digit (depending on report format) primary subscriber account
number. Each number requires a 2-digit entry so as to allow entry of
hexadecimal digits (B-F). If a 3-digit account number is to be used, enter data
only in the first 3 locations, and enter * in the fourth location.
NOTE: This field must be programmed if a secondary phone number is used
(field *34). This account number can be the same as the primary account
number.
Select the options for the printer port for event log printing.
If you are using the printer port for printing of the event log, select if the ACK
signal is required.
Select the baud rate of the data on the printer port.
If enabled, the system allows the bypassing of fire zones.
If enabled, the system suppresses the displays of all keypads while the
system is armed. This includes alarms, troubles, etc.
NOTE: If enabled, no prompts are displayed for disarming, including prompts
for global-disarming. Also, voice annunciations are suppressed on all devices
(ex. 5804BDV).
EXPLANATION
Section 5 - Data Field Descriptions
5-7