VISTA-120 Installation and Setup Guide
Check or TRBL Display
1*07
0 = CHECK
1 = TRBL
Suppress Use of Armed LED on
1*08
Keypads
0 = disable
1 = enable
Suppress Keypad Arming Status
1*09
Indications When System is Armed
0 = disable
1 = enable
First to Alarm Display Lock
1*10
0 = scroll alarms
1 = lock display
Common Area 1 Partition
1*11
Enter 1-8
0 = none
Affects Common Area 1 (partition-
1*12
specific)
0 = disable
1 = enable
Arms Common Area 1 (partition-
1*13
specific)
0 = disable
1 = enable
Common Area 2 Partition
1*14
Enter 1-8
0 = none
Affects Common Area 2 (partition-
1*15
specific)
0 = disable
1 = enable
Arms Common Area 2 (partition-
1*16
specific)
0 = disable
1 = enable
Common Area 3 Partition
1*17
Enter 1-8
0 = none
Affects Common Area 3 (partition-
1*18
specific)
0 = disable
1 = enable
Arms Common Area 3 (partition-
1*19
specific)
0 = disable
1 = enable
Auto Bypass Logic
At the end of the exit delay, if a door is left open or an interior zone is faulted, the system starts the entry delay period,
and sounds the bell/siren(s) and keypad sounders for the duration of entry delay. This gives the user time to re-enter the
premises and disarm the system before auto bypass occurs. If field *07 is enabled, the faulted zone(s) are auto bypassed
5-8
Select whether the system should display TRBL or CHECK for trouble
conditions.
If enabled, the system suppresses the armed LED when the system is in the
armed state. This is for countries where the Red is only for indicating alarm.
If enabled, the system suppresses all arming status indications when the
system is armed, but alarms, troubles, etc. will be displayed.
NOTE: If enabled, no prompts are displayed for disarming, including prompts
for global-disarming. Also, voice annunciations are suppressed on all devices
(ex. 5804BDV). The arming status is NOT suppressed on any Master
Consoles.
If lock display is selected, the system displays of first fire alarm and requires
the user to press the [*] key for a display of each additional fire alarm.
Otherwise, the system automatically scrolls all fire alarms.
Enter the common area 1 partition.
If enabled, causes common area 1 to disarm when this partition disarms.
NOTE: This partition must be armed before common area 1 can be armed.
If enabled, arming this partition causes the system to attempt to arm common
area 1 automatically. To enable this field, field 1*12 must also be enabled
(partition-specific).
NOTE: Common area 1 cannot be armed unless all partitions programmed for
"affect" (field 1*12) are already armed.
Enter the common area 2 partition.
If enabled, causes common area 2 to disarm when this partition disarms.
NOTE: This partition must be armed before common area 2 can be armed.
If enabled, arming this partition causes the system to attempt to arm common
area 2 automatically. To enable this field, field 1*15 must also be enabled
(partition-specific).
NOTE: Common area 2 cannot be armed unless all partitions programmed for
"affect" (field 1*15) are already armed.
Enter the common area 3 partition.
If enabled, causes common area 3 to disarm when this partition disarms.
NOTE: This partition must be armed before common area 3 can be armed.
If enabled, arming this partition causes the system to attempt to arm common
area 3 automatically. To enable this field, field 1*18 must also be enabled
(partition-specific).
NOTE: Common area 3 cannot be armed unless all partitions programmed for
"affect" (field 1*18) are already armed.