VISTA-120 Installation and Setup Guide

Programming Access Control of an Entry/Exit Point

VistaKey
See the VistaKey-SK-EX Installation and Setup Guide
for the detailed programming instructions.
VistaKey Dialer Enables
When the VistaKey is installed with an alarm system,
the system defaults are set so that the system does not
send reports to the central station. The programming is
accomplished in field 1∗32 for the following events:
ACS Troubles - To enable or disable ACS trouble
reporting.
ACS Bypasses - To enable or disable ACS bypass
reporting.
ACS System - To enable or disable ACS system
reporting, (i.e., ACS module reset).
ACS Alarms - To enable or disable ACS alarm
reporting.
Dialer (Trace) - To enable or disable access
grant/denial events sent to the central station.
PassPoint
The PassPoint ACS can dedicate some of its inputs for
use as regular VISTA-120 hardwired zones (the zone
response type is ACS). The PassPoint ACS can also
utilise the VISTA-120 control panel dialler for reports
to the central station.
Using ACS Zone Inputs
If the PassPoint ACS has uncommitted zones, these
may be used by the VISTA-120 as wired zones. To
program for ACS zone inputs, perform the following
steps:
Step
Action
1
Enter Zone Programming in the #93 Menu
Mode.
2
Program this zone as any other zone. Indicate
the input type as ACS (10).
3
Enter the PassPoint ACS's zone ID (00-31)
See Zone Programming in the Programming Guide for a
detailed explanation.
PassPoint Dialler Events
All PassPoint ACS events can be sent to the VISTA-120
dialler via the VGM. These events will also be logged
into the control's event log. This is enabled in the
PassPoint ACS. See the PassPoint ACS documentation
for a detailed explanation.
Programming the VISTA Gateway Module
See the PassPoint ACS instructions to program the
VISTA Gateway Module.
Access Control of an Entry/Exit Point Using VistaKey
or PassPoint
The control can send entry and exit requests to the
VistaKey or PassPoint ACS utilising keypads and
button-type (BR) RF transmitters. A zone is
programmed with a response type 27 (Access Point) and
an appropriate input type (console, RF).
4-8
Using the Alpha Keypad
Step
Action
1
Enter Zone Programming in the #93 Menu
Mode.
2
Program the zone with a response type 27
(Access Point).
3
Enter the access point number (00-31) of the
door.
4
Program whether this is an entry or exit point.
5
Enter the partition number.
6
Enter the input type as CS (09).
7
Enter the keypad ECP address.
See Zone Programming in the Programming Guide for a
detailed explanation.
Using an RF Transmitter Zone
A button type RF transmitter
(5804/5804AP/5804EU/5804H) can be used to provide
access or egress for up to 4 doors. One button will
control one door. Also, a button can be used to provide
access or egress due to a panic or duress condition.
An RF transmitter (5816/5816AP/5816EU/5816H) can
be used with a remote switch to provide exit in case of a
fire alarm using a PassPoint event action.
The PIR (5890/5890AP/5888EU/5888H) can be used to
provide exit while preventing entry through a door.
The smoke detector (5808LST/5808EU/5808H) can be
used to provide egress in emergency situations. To
program the RF transmitter for access control, perform
the following steps:
Step
Action
1
Enter Zone Programming in the #93 Menu
Mode.
2
Program the zone with a response type 27
(Access Point).
3
Enter the access point number (00-31) of the
door.
4
Indicate whether RF device is for entry or exit.
5
Enter the partition number
6
Enter the input type: button RF (05).
7
Enter the loop number.
8
Enroll the serial number
See Zone Programming in the Programming Guide for a
detailed explanation.
RF buttons and pendants must be assigned to
a user number in order to function. See
SECTION 9: User Access Codes for the
procedure.
An RF transmitter will not provide access or
grant if the system is in any test mode.