Zone 5 Audio Alarm Verification
1*60
0 = disable
1 = enable
Display Tamper
1*61
0 = disable
1 = enable
Tamper Detect in Test Mode
1*62
0 = disable
1 = enable
Silence Sounder During AAV
1*66
0 = disable
1 = enable
Video Alarm Verification
1*67
0 = disable
1 = enable
Event Log Types
1*70
0 = disable
1 = enable
12/24 Hour Time Stamp Format
1*71
0 = 12-hour
1 = 24-hour
Event Log Printer On-Line Mode
1*72
0 = disable
1 = enable
Printer Baud Rate
1*73
0 = 1200 (preferred)
1 = 300
Relay Timeout XXX Minutes
1*74
Enter 000-127 times 2 minutes (000-254).
Relay Timeout YYY Seconds
1*75
Enter 000-127 seconds.
Access Control Relay (partition-
1*76
specific)
01-96 = relay number
00 = relay not used.
Log First Maintenance Signal
1*77
0 = no logging
1 = log first maintenance signal from each
smoke detector
Number of Partitions
2*00
Enter 1-8.
FIELD
TITLE and DATA ENTRIES
If enabled, zone 5 is used for 2-way audio (AAV).
NOTE: Zone 5 cannot be used as protection zone.
If enabled, the system displays "Tamper" instead of "Check" or 'Trbl" (see field
1*07).
If enabled, the system terminates the test mode and displays the tamper
condition.
If disabled, the system remains in test mode and displays "fault."
If enabled, the system silences the alarm sounder and the keypad when AAV
is being used and listening microphones are on.
If enabled, the system transmits the Contact ID code 609 so the central
station equipment can be ready for video image reception and processing.
This field has five entries as follows: Alarm, Check, Bypass, Open/Close,
System.
If enabled, the system logs those types of events into the event log.
NOTE: Events are also logged into the PassPoint system, if installed.
Select the type of time stamping for the event log.
If enabled, the system prints the events as they occur.
If disabled, the system prints the log only upon request.
Select the baud rate for the serial printer.
This is used for #80 Menu Mode Time-Driven event relay command numbers
"04/09" and Output Programming in the #93 Menu Mode Programming output
command "56."
This is used for #80 Menu Mode Time-Driven event relay command numbers
"05/10" and Output Programming in the #93 Menu Mode Programming
command "57."
If enabled, the assigned relay closes for 2 seconds when the user enters his
code and presses 0.
Select whether the system should log the first maintenance signal from each
smoke detector.
Enter the number of partitions used in the system.
EXPLANATION
Section 5 - Data Field Descriptions