Honeywell ADEMCO VISTA-120 Installation And Setup Manual page 29

Partitioned security system with scheduling
Hide thumbs Also See for ADEMCO VISTA-120:
Table of Contents

Advertisement

Each transmitter's zone number is programmed into
the system in # 93 mode. Some transmitters, such as
the 5816, 5816AP, 5816EU, 5816H and 5817, can
support more than one "zone" (referred to as loops or
inputs). On the 5816/5816AP/5816EU/5816H for
example, the wire connection terminal block is loop 1,
the reed contact is loop 2. Each loop must be assigned a
different zone number and enrolled separately.
For button transmitters (wireless "keys), such as the
5804, and, you must assign a unique zone number to
each individual button used on the transmitter. Each
button on the transmitter also has a pre-designated
loop or input number, which is automatically displayed
when enrolled.
5800 Series Transmitter Supervision
Except for some transmitters that may be carried off-
premises (5802, 5802AP, 5802CP, 5804, 5804AP
5804EU, 5804BD, 5827, 5827AP), each transmitter is
supervised by a check-in signal that is sent to the
receiver at 70–90 minute intervals (25 minutes for
5800EU and 9 minutes for 5800H series). If at least one
check-in is not received from each supervised
transmitter within a programmed time period (i.e., 24
hours for 5800 or 2 hours for 5800EU/5800H), the
"missing" transmitter number(s) and "CHECK" will be
displayed.
The supervision for a particular transmitter that may
be carried off the premises (5801, 5802AP, 5802MN,
5802MN2, 5802EU, 5802H) may be turned off by
enrolling it as a "UR" (Unsupervised RF) type, as
described later.
5800 series transmitters have built-in tamper
protection and will cause a "CHECK" or "TRBL"
condition to be annunciated if covers are removed,
provided that program field *24 (Disable Expansion
Zone Tamper) is set for "0." 5800EU series transmitters
(5816EU, 5819EU, 5839EU and 5888EU) and 5800H
series transmitters (5814H, 5816H, 5819H, 5819SH,
5839H, 5852H, and 5888H) are also tamper protected
against wall removal.
5800 Series Transmitter Battery Life
Batteries in the wireless transmitters may last from 4-7
years, depending on the environment, usage, and the
specific wireless device being used. External factors
such as humidity, temperature, as well as large swings
in temperature may all reduce the actual battery life.
The wireless system can identify a low battery situation
when the battery still has 30 days of life remaining,
thus allowing the dealer or user of the system time to
arrange a change of battery and maintain protection for
that given point within the system.
Some transmitters (e.g., 5802 and 5802CP) contain
long-life but non-replaceable batteries. At the end of
their life, the complete unit must be replaced (and a
new serial number enrolled by the control).
Button type transmitters (ex. 5801, 5802, 5802AP,
5802CP, 5804, 5804AP, 5804H and 5804EU) should be
periodically tested by the user for battery life.
Section 3 – Installing the Control
Do not install batteries in wireless transmitters
until ready to enroll them. This is to avoid
interference. It is not critical to remove
batteries after enrolling.
Compatible 5800 Series Transmitters
Model
Product
5801
Panic Transmitter
5802
Pendant (Personal
Emergency Transmitter)
5802CP
Belt Clip (Personal
Emergency Transmitter)
5802MN/
Miniature (Personal
5802AP
Emergency Transmitter)
5802MN2
2-Button (Personal
Emergency Transmitter)
5802EU/
2-Button (Personal
5802H*
Emergency Transmitter)
5804/
RF Key Transmitter
5804AP
5804EU/
RF Key Transmitter
5802H*
5804BD
RF Key Bi-directional
Transmitter
5806/
Photoelectric Smoke
5808LST/
Detectors
5808EU/
*
5808H
5816/
Door/Window Transmitter
5816AP
5816EU/
Door/Window Transmitter
*
5816H
5816MN
Miniature Door/Window
Transmitter
5816TEMP
Temperature Sensor
Transmitter
5817
Multi-Point Universal
Transmitter
5818
Recessed Transmitter
5819/
Shock Sensor Analyzer
5819EU/
Transmitter
*
5819H
5819S/
Shock Sensor Analyzer
5819EUS/
Transmitter
*
5819SH
5827/
Wireless Keypad
5827AP
5827BD
Wireless Bi-directional
Keypad
5849
Glassbreak Detector
5852/
Glassbreak Detector
*
5852H
5888EU/
PIR Detector
*
5888H
5890
PIR Detector
5890PI/
PIR Detector with Pet
5890AP
Immunity
*
CE approved and specifically type-approved in
Finland, France, Germany, Italy, Netherlands, Norway,
Portugal, Spain, Sweden, and Switzerland.
Input Type
UR or RF
BR Only
UR or RF
UR or RF
UR or RF
BR Only
BR Only
BR Only
RF
RF
RF
RF
RF
RF
RF
RF
RF
House ID
House ID
RF
RF
RF
RF
RF
3-11