VISTA-120 Installation and Setup Guide
Country Code
*55
00 = Latin America, Spain, Italy, Eastern
Europe, China
01 = Australia
02 = Belgium
03 = Denmark
04 = Finland
05 = France
06 = Netherlands
07 = Norway
08 = Sweden
Contact ID Data on Keypad Bus for
*56
Alternative Communications Media
Reporting Instead of Digicom
0 = disable
1 = enable
Contact ID Data on Keypad Bus for
*57
Back-up Alternative Communications
Media Reporting if Digicom Fails
0 = disable
1 = enable
Long Range Radio Central Station #1
*58
Category Enable
0 = disable
1 = enable
Long Range Radio Central Station #2
*59
Category Enable
0 = disable
1 = enable
Verified Alarm Report Enable
*60
0 = disable
1 = enable
Robofon Version of Contact ID
*61
0 = disable
1 = enable
Zone Type Restores for Zone Types
*79
1-8
0 = disable
1 = enable
Zone Type Restores for Zone Types
*80
9 and 10
0 = disable
1 = enable
First Test Report Time
*83
Enter 00-07 for the day (01 = Monday)
Enter 00-23 for the hour
Enter 00-59 for the minutes
FIELD
TITLE and DATA ENTRIES
5-6
Enter the country code to enable the proper telephone system for the dialler.
NOTE: selections 01 – 07 require special hardware configuration.
Select which Contact ID messages will be transmitted on the Keypad bus for
subscriber #1. The messages are as follows: Alarms, Troubles, Bypasses,
Open/Close, System Conditions, Test Reports.
Select which Contact ID messages will be transmitted on the Keypad bus for
subscriber #2. The messages are as follows: Alarms, Troubles, Bypasses,
Open/Close, System Conditions, Test Reports.
If enabled, a special Contact ID report is transmitted if 2 burglary alarms are
detected within 45 minutes (Swedish requirement).
If enabled, the system uses Robofon version of Contact ID (Swedish
requirement).
This field has eight entries, one for each zone type. Select the zone types that
will send Restore reports.
This field has two entries, one for each zone type. Select the zone types that
will send Restore reports.
Enter the day and time that the first Test report shall be transmitted. Enter 00
in all locations if the Test report is to be sent immediately upon exiting. Enter
00 in the day location if the report is to be sent at the next occurrence of the
time that is set.
EXPLANATION