VISTA-120 Installation and Setup Guide
Optional VISTA Interactive Phone Module
Supports the ADEMCO 4286 VIP Module* or
TeleCommand**, that permits access via telephone to
do the following:
Obtain system status information
Arm and disarm security system
Control relays and/or Powerline Carrier devices
* English language version only
**English, French, Italian, Spanish, Portuguese
and Chinese
Supervisory Zones
Provides zones for supervision of the following:
J7 Trigger Outputs
RF Receivers
Polling Loop
Keypad Panic Keys
Accommodates three keypad panic keys: 1 + ✴ (A),
✴ + # (B), and 3 + # (C).
Designated as zones 995 (1 + ✴), 996 (3 + #), and
999 (✴ + #)
Activated by wired and wireless keypads
Activated and reported separately by partition,
distinguished by Subscriber Acct. No. (or Partition
No. if Contact ID reporting is used)
8 Partitions
Provides the ability to control 8 separate areas
independently, each functioning as if it had its own
separate control. Partitioning features include:
Up to 3 "Common Area" partitions, which arm
automatically when the last partition (1-8) that
shares the common area is armed and disarms
when the first partition (1-8) that shares the
common area is disarmed
A Master Partition (9) to which keypads may be
assigned to view the status of all 8 partitions at
the same time
Keypads assignable to one of 8 partitions or to
Master Partition 9 to view system status
Ability to assign Relays/Powerline Carrier devices
to one or all 8 partitions
Certain system options selectable for each
partition, such as Entry/Exit Delay and Subscriber
Account Number
1-2
Zone 973
Zones 988, 990
Zone 997
User Codes
Accommodates 150 user codes, all of which can operate
any or all partitions. Each user, if assigned to more
than one partition, retains the same user number
across all partitions, and will only utilise one user "slot"
in the system. Certain characteristics must be assigned
to each user code as follows:
Authority level for each partition (Master,
Manager, or several other Operator levels)
Opening/Closing central station reporting option
What partitions the code can operate
Global arming capability (arm and disarm all
partitions the code has access to in one command)
Use of a wireless transmitter to arm and disarm
the system (wireless transmitter must first be
"enrolled" into the system
Pass Point Access Control System (ACS)
If the PassPoint ACS has uncommitted zones, up to 32
of these zones can be used as if they were basic wired
zones, as long as they are within VISTA-120's total
capacity of 128 protection zones.
Keypad Macros
Accommodates up to 4 keypad macro commands per
partition (each macro is a series of keypad commands),
which can be assigned to the A, B, C and D keys on
each partition's keypads.
This means, for example, that by pressing the "D" key,
the system can be programmed to log onto another
partition, bypass zones 2 and 3, and arm that partition
in the AWAY mode (explained in detail later in this
manual). Each macro can be up to 32 characters in
length.
Optional Output Devices (4204 Relays and Powerline
Carrier [i.e., X-10] Devices)
Accommodates the use of 32 output devices, which can
be a combination of ADEMCO's 4204 Relay Modules or
Powerline Carrier Devices (i.e., X-10), and up to 64
polling loop relay outputs (1 per 4101SN). Each 4204
module provides four "Form C" relays for general
purpose use.
Powerline Carrier Devices are controlled by signals sent
through the electrical wiring at the premises via a 4300
transformer or other appropriate modulator (e.g. XM10E
in Europe; XF10 in Australia). Therefore, if using
Powerline Carrier Devices, a 4300 (110V) or XF10
(220V) transformer must be used in place of the regular
system transformer (plug-pack) in the markets using
those devices. Elsewhere, the power transformer and the
line carrier modulator are separate (Europe/XM10E).
Output devices have the following characteristics:
Can activate in response to system events
Can activate using time intervals
Can be activated manually using the #70 relay
command mode
Can each have an alpha descriptor assigned to it
Can be activated remotely from the PC downloader
during the download session