Operating Problems - Wexiodisk WD-215T Installation And User Manual

Tray dishwasher
Hide thumbs Also See for WD-215T:
Table of Contents

Advertisement

Instructions for use

4.3.5 Operating problems

ALARM MESSAGE
(0)
PLATFORM ERROR
(63) POWER SUPPLY
FAILURE
CHECK THE
EMERGENCY SWITCH
(98) HARDWARE ERROR
POWER ON FUNCTION
DEFECT
CALL SERVICE
(1)
EMERGENCY STOP
ACTIVATED
Remove the cover plate (B) from the condensing battery by unscrewing the
wing nuts which fasten it in place. Lift up the condensing battery using the
lifting arm (C) to make it easier to remove.
Check from inside the machine that the drain (E) under the battery is not
blocked.
With the condensing battery removed, begin by cleaning the bottom plate
of the battery box. Then check that the drain (E) is not blocked.
Next, clean the condensing battery (D). Rinse between the cooling fins
from above. If the condensing battery is very dirty, a cleaning product with
a neutral pH which will dissolve grease can be used. Check the drain.
Finish by washing the base of the battery box again.
Replace the condensing battery using the lifting arm (C), attach the cover
plate securely (B) using the wing nuts, before fitting the top panel (A).
Check:
Has the appliance been used according to the instructions?
Are all the removable parts in their correct place?
Is the main switch in the ON position?
Are there any error messages on the display?
Are the fuses in the electrical cabinet still intact? Ask service personnel to
check the fuses.
Error messages
Machine faults and user faults are indicated by messages on the display (1). The
alarms indicated with a flashing LED (8) can be reset by pressing button (9) when
the cause of the alarm has been rectified.
The following alarms can be addressed by the operator. For other alarms, or if an
alarm reset with button (9) recurs, authorised service personnel must be contac-
ted.
ACTION
Restart the machine.
Reset the emergency stop by turning it in the direction of the arrows. Restart the
machine.
Restart the machine. If the error recurs, contact an authorised service company.
Reset the emergency stop by turning it in the direction of the arrows. Start the
feed by pressing button (5).
WD-215T
42
Rev. 6.0 (201812)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wd-275t

Table of Contents