ALARM MESSAGE
(100)
NOMINAL VALUES
RESTORED FROM UI
(4)
COMMUNICATION
ERROR BETWEEN
CPU AND I/O 1
CALL SERVICE
(5)
COMMUNICATION
ERROR BETWEEN
CPU AND I/O 2
CALL SERVICE
(6) COMMUNICATION
ERROR BETWEEN
CPU AND EXTRA CARD
CALL SERVICE
(7) COMMUNICATION
ERROR BETWEEN
CPU AND DISPLAY CARD
CALL SERVICE
(14) WEAK SIGNAL
FROM PHOTOCELL
START WASH
CLEAN PHOTOCELL
(47) HACCP ALARM
PUMP FUNCTIONALITY
DEFECT
PRESS RESET
(64) HACCP ALARM
WRONG TEMPERATURE
IN TANK
PRESS RESET
(67) HACCP ALARM
WRONG TEMPERATURE
IN BOILER
PRESS RESET
(72) HACCP ALARM
WASHING DETERGENT
FUNCTIONALITY DEFECT
PRESS RESET
(78) HACCP ALARM
FINAL RINSE
DEFECT
PRESS RESET
(29)
EXTERNAL ALARM
INPUT ACTIVATED
(30)
TIMEOUT FILLING
OF TANKS
PRESS RESET
WD-215T
ACTION
Reset the alarm by pressing button (9). If the error recurs, contact an authorised
service company.
Restart the machine.
Restart the machine.
Restart the machine.
Restart the machine.
Clean the photocell. The alarm in the display will disappear after cleaning.
Reset the alarm by pressing button (9). If the error recurs, contact an authorised
service company.
Reset the alarm by pressing button (9). If the error recurs, contact an authorised
service company.
Reset the alarm by pressing button (9). If the error recurs, contact an authorised
service company.
Check and fill with new detergent. Reset the alarm by pressing button (9).
Open the tap. Clean the nozzles. Reset the alarm by pressing button (9).
Reset the alarm by pressing button (9). If the error recurs, contact an authorised
service company.
Open the stopcocks. Close the level pipe and the outlet seals. Check the rubber
sleeves. Reset the alarm by pressing button (9).