Operating Problems - Wexiodisk WD-8 Installation And User Manual

Table of Contents

Advertisement

Operating instructions

4.3.6 Operating problems

CODE
CAUSE
IF01 /
The time needed to fill the tank has been
Er01
exceeded.
The level pipe is not in place.
The level pipe's rubber sleeve is not
sealing against the bottom plate.
The water stopcock is closed.
Er02
It has taken too long for the machine to
heat up, compared with the previous time.
Er04
Faulty temperature sensor.
Er05
Faulty temperature sensor.
IF06 /
The booster heater is not cooled during
Er06
the final rinse phase.
The water stopcock is closed.
IF09
Alarm for changing the water.
IF10
Alarm for weekly cleaning.
Er12
The break tank has not been filled with
water.
Er13
The level sensor in the break tank
indicates an incorrect signal.
Check:
Has the appliance been used according to the instructions?
Are all the removable parts in their correct place?
Is the main switch in the ON position?
Are there any error messages on the display?
Are the fuses in the electrical cabinet still intact? Ask service personnel to
check the fuses.
Error messages
During operation, various alarms or information messages can appear on the
panel's display. There is a distinction between IF and Er alarms. IF alarms can
normally be dealt with by the operator. If there is an Er alarm, the service
personnel must be called. Some IF alarms that have been dealt with by the
operator a few times will eventually change to Er alarms, meaning that the service
personnel must be contacted.
Each alarm has a number: 01, 02, 03 etc. The top display shows either IF or Er.
The bottom display shows the alarm number.
WD-8
ACTION
The alarm can be reset by pressing 0/1 on the panel.
Fit the level pipe.
Adjust the level pipe. Check that the rubber sleeve has
not been damaged. Replace the sleeve, if it is
damaged.
Open the stopcock.
The alarm can be reset by pressing 0/1 on the panel.
Contact service personnel if the alarm recurs.
Contact service personnel.
Contact service personnel.
The alarm can be reset by pressing 0/1 on the panel.
Open the stopcock. Close the hood.
Change the water. The alarm can be reset by pressing
0/1 on the panel. If the alarm is not set to stop the
machine, the washing programme can continue.
The machine must be cleaned more thoroughly than
during daily cleaning. The alarm can be reset by
pressing 0/1 on the panel.
The alarm is reset automatically when the tank is full.
The alarm is reset automatically when the tank is full.
47