Technical information
Connection, electrically-heated machines
Max. connection area 230 V 3~ (L1-L3, PE) Cu (mm²)
* Other voltages on request
Connection, steam-heated machine 50-140 kPa
Total connected power (kW)
Main fuse 400 V 3N~ (A)
Max. connection area 400 V 3N~ (L1-L3, N, PE) Cu (mm²)
Main fuse 230 V 3~ (A)
Max. connection area 230 V 3~ (L1-L3, PE) Cu (mm²)
Steam connection (internal thread)
Condensing water connection (internal thread)
* Other voltages on request
Connection, steam-heated machines 150-250kPa
Total connected power (kW)
Main fuse 400 V 3N~ (A)
Max. connection area 400 V 3N~ (L1-L3, N, PE) Cu (mm²)
Main fuse 230 V 3~ (A)
Max. connection area 230 V 3~ (L1-L3, PE) Cu (mm²)
Steam connection (internal thread)
Condensing water connection (internal thread)
* Other voltages on request
Water, drain and ventilation connections
Water quality (hardness ) (° dH)
Hot water connection, 50-65° C (internal thread)
Cold water connection, 5-12° C (internal thread)
Drain connection, PP - pipe (ø mm)
Water capacity, cold water, pressure (kPa)
Water capacity, cold water, flow (litres/minute)
Water capacity, hot water, min./max. pressure (kPa)
Floor drain, capacity (litres/sec.)
Heat load room, sensitive (kW)
Heat load room, latent (kW)
Heat load room, total (kW)
Capacity heat recovery fan (m³/hour)
Size and weight for transport
Size * ( LxWxH ) (m)
Weight * (kg)
** Including packaging
WD-215T
*
*
*
*
47
Rev. 6.0 (201812)
70
12
32
35
35
35
R¾"
R½"
12
32
35
35
35
R¾"
R½"
2-7
R½"
R½"
50
250-600
6
100/600
3
4.5
3
7.5
100
2.7x0.8x2.0
510