Solid State Logic C10 HD Installation Manual page 215

Digital broadcast console
Table of Contents

Advertisement

c10 hd SnMp t
RApS
The standard 'trap' objects that are available for the C10 HD system in V1.1/5 software are shown in the following table.
object
sslC10Restarting
sslC10MemLow
sslC10DspReboot
sslC10DspRebootFail
sslC10Psu1Fail
sslC10Psu2Fail
sslC10MainGfx1Fail
sslC10MainGfx2Fail
sslC10LostTileComms
sslC10ResumedTileComms
sslC10Synclost
sslC10SyncReturned
sslC10NowActiveInRedundantPair
sslC10NowDormantInRedundantPair
sslC10DiskStatusNotify
sslC10RaidStatusNotify
C10 HD Installation Manual
From
description
System
System restarting
System
Blackrock DSP card memory low
System
A DSP device on the Blackrock DSP card has rebooted
A DSP device on the Blackrock DSP card has failed to
System
reboot
Processor
Blackrock processor PSU 1 failure
Processor
Blackrock processor PSU 2 failure
Console
Primary console TFT meter driver failure
Console
Secondary console TFT meter driver failure
System
Lost Ethernet communication to the control surface
Recovered Ethernet communication with the control
System
surface
System
External (Video/AES) sync lost
System
External (Video/AES) sync recovered
Blackrock processor is now the active member of a
System
redundant pair
Blackrock processor is now the dormant member of a
System
redundant pair
SBC system disk SMART status trap. This will be sent upon
SBC
receiving a SMART error from the system hard disks
SBC RAID disk array status trap. This will be sent upon
SBC
receiving a change in status from the system RAID disk
array manager