Front Panel Menu
Pressing on any line in the screen will bring up an information pop-up for that tile. The only information you are likely to
need from this page is the firmware type, shown at the bottom, which a Service engineer may ask you to provide. You
can also set the tile's IP address:
The frame number for your front panel is displayed in the top left-hand corner of the main ethernet FP Setup screen.
To edit this, press the blue box containing the 'Selected frame' number to bring up the Enter Frame ID pop-up:
Frame numbers run from 1 to 15. Frame 0 is reserved and means 'not in a frame'. The frame number for your front panel
must be unique on the network it is on.
The use retries box in the main ethernet FP Setup screen allows you to choose whether or not the CPU
automatically retries communications with tiles when they time-out.
The broadcast address is set to 192.168.25.255 by default. Set it to something suitable if you have different IP settings to
those suggested above.
C10 HD Installation Manual
Section 5: System Administration
|
Page 5-53
Need help?
Do you have a question about the C10 HD and is the answer not in the manual?