8 Troubleshooting and Maintenance
Code
Description
010
Grid failure (Islanding)
DC
over-current.
The
011
injection of AC current
exceeds
limit.
Leakage
over-current.
012
The leakage current
exceeds
allowable upper limit.
10-minute
over-voltage.
The
014
voltage in 10 minutes
exceeds
permissible range.
Grid over-voltage
The
exceeds the protective
015
value, which is higher
than
value of error 002.
(stage II)
The bus voltage or
016
power is high.
Bus
over-voltage.
The
019
voltage
inverter
upper limit.
Bus over-voltage.
The
020
exceeds
allowable upper limit.
56
injection
DC
current
the
upper
current
inverter
grid
average
grid
the
grid
voltage
the
protective
transient
transient
bus
exceeds
allowable
bus
voltage
inverter
Troubleshooting
1. Check whether AC circuit breaker is
triggered.
2. Check whether AC cables are all firmly
connected.
3. Check whether grid is not in service.
4. If all conditions are OK and this fault still
occurs in the LCD screen, contact Sungrow
Service Dept.
1. Wait a moment for inverter recovery.
2. If the fault occurs repeatedly, contact
Sungrow Service Dept.
1. Check the PV strings for ground fault.
2. If the fault occurs repeatedly, contact
Sungrow Service Dept.
1. Check whether the inverter selected
country code is the country you are in.
2. Wait a moment for inverter recovery.
3. Check the voltage of the grid. If the grid
voltage exceeds the permissible range of
inverter protection parameters, ask utility
grid company for solution.
4. If the fault occurs repeatedly, contact
Sungrow Service Dept.
1. Check the model of the AC cables.
2. Wait a moment for inverter recovery.
3.
If
the
grid
permissible range, ask utility grid company
for solution.
4. If the fault occurs repeatedly, contact
Sungrow Service Dept.
1. Wait a moment for inverter recovery.
2. If the fault occurs repeatedly, contact
Sungrow Service Dept.
1. Wait a moment for inverter recovery.
2. If the fault occurs repeatedly, contact
Sungrow Service Dept.
1. Wait a moment for inverter recovery.
2. If the fault occurs repeatedly, contact
Sungrow Service Dept.
User Manual
voltage
exceeds
the

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SG2K5-S and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Sg2k-sSg3k-sSg3k-dSg5k-dSg8k-d

Table of Contents