Configure Gas Standard Volume Flow Unit

Display
ProLink III
Field Communicator Configure > Manual Setup > Measurements > GSV > GSV Flow Unit
Overview
Gas Standard Volume Flow Unit specifies the unit of measure that will be displayed for the
gas standard volume flow. The measurement unit used for the gas volume total and the
gas volume inventory is derived from this unit.
Prerequisites
Before you configure Gas Standard Volume Flow Unit, be sure that Volume Flow Type is set
to Gas Standard Volume.
32
Set Polling Control n as one of the following options:
The n is the value you selected in the Polling Slot field.
If there is another master, and if that master is primary, then set this field to
secondary. If the other master is secondary, then set this field to primary.
Option
Description
Poll as Primary
No other HART masters will be on the network.
Poll as Secondary
Other HART masters will be on the network.
Set External Device Tag n to the HART tag of the device being polled.
The n is the value you selected in the Polling Slot field.
The device being polled (slave) cannot have special units set for density.
Otherwise, the master will reject the base density and report the following alarm:
A115: No External Input or Polled Data Alert
On the slave side, setup the HART Primary Variable for Base Density. The master
will reject anything other than Base Density for the HART Primary Variable and
trigger an A115 alarm.
The density units on the transmitter and the polled device can be different as
long as they can be classified as density units; for example, kg/m
The transmitter converts the polled units into compatible specified units.
For wiring and setup instructions for a polled device, refer to the Micro Motion Gas
Density Meters (GDM) Installation manual or the Micro Motion Specific Gravity Meters
(SGM) Installation manual.
Continue to
Section
4.3.3.
OFF-LINE MAINT > OFF-LINE CONFG > UNITS > GSV