  • Page 1 Quick Start Guide 00825-0100-4108, Rev EA February 2019 ™ Rosemount 2088, 2090F, and 2090P Pressure Transmitter ® with 4–20 mA HART and 1–5 Vdc Low Power HART Protocol (Revision 5 and 7)
  • Page 2: Table Of Contents

    February 2019 Safety messages for Rosemount 2088,2090F, and 2090P Transmitters. NOTICE This guide provides basic guidelines for Rosemount 2088,2090F, and 2090P Transmitters. It does not provide instructions for configuration, diagnostics, maintenance, service, troubleshooting, Explosion-proof, Flameproof, or intrinsically safe(I.S.)installations. See the Rosemount 2088 Reference Manual for more information.
  • Page 3: System Readiness

    3. Select desired product. a) Reference Table 1-1 Table 1-2, Find Device Driver Files column to find the correct device driver. Table 1-1: Rosemount 2088 and 2090 with 4–20 mA HART Device Revisions and Files Release Device identification Device driver Review...
  • Page 4 Quick Start Guide February 2019 Table 1-1: Rosemount 2088 and 2090 with 4–20 mA HART Device Revisions and Files (continued) Release Device identification Device driver Review Review date identification instructions functionality NAMUR HART revision Device Reference Change revision revision manual...
  • Page 5 February 2019 Quick Start Guide To access new functionality, the new device driver must be downloaded. It is recommended to download new device driver files to ensure full functionality. HART Revision 5 and 7 selectable, Local Operator Interface(LOI), scaled variable, configurable alarms, expanded engineering units.
  • Page 6: Mount The Transmitter

    Quick Start Guide February 2019 Mount the transmitter ™ Rosemount 2088 Mount directly to the impulse line without using an additional mounting bracket or mount directly to a wall, panel, or two-inch pipe using an optional mounting bracket. ™ Rosemount 2090P Mount directly to the process pipe using an existing weld spud, or have a skilled welder install a new weld spud using a TIG welder.
  • Page 7 February 2019 Quick Start Guide Figure 2-2: Panel and Pipe Mounting Panel mount Pipe mount Liquid flow applications Transmitter mounting procedure for liquid flow applications. Procedure 1. Place taps to the side of the line. 2. Mount beside or below the taps. Example Gas flow applications Transmitter mounting procedure for gas flow applications.
  • Page 8 Quick Start Guide February 2019 Example Steam flow applications Transmitter mounting procedure for steam flow applications. Procedure 1. Place taps to the side of the line. 2. Mount beside or below the taps. 3. Fill impulse lines with water. Example Environmental seal for housing Thread sealing (PTFE) tape or paste on male threads of conduit is required to ®...
  • Page 9 February 2019 Quick Start Guide Gage transmitter orientation The low side pressure port (atmospheric reference) on the gage transmitters with aluminum housings are located in the neck of the transmitter, behind the housing. The vent path is 360° around the transmitter between the housing and sensor.
  • Page 10: Set The Switches

    Quick Start Guide February 2019 Set the switches Set alarm and security switch configuration before installation as shown in Figure 3-1. • The alarm switch sets the analog output alarm to high or low. Default alarm is high. • The security switch allows ( ) or prevents ( ) any configuration of the transmitter.
  • Page 11 LOI/LCD display The LOI/LCD display can be removed and rotated as needed by following the “Rotating LOI/LCD display” instructions in the Rosemount 2088 Reference Manual. Quick Start Guide...
  • Page 12: Connect The Wiring And Power Up

    Quick Start Guide February 2019 Connect the wiring and power up Shielded twisted pair cable should be used for best results. Use 24 AWG or larger wire that does not exceed 5000 ft. (1500 m) in length. If applicable, install wiring with a drip loop. Arrange the drip loop so the bottom is lower than the conduit connections and the transmitter housing.
  • Page 13 February 2019 Quick Start Guide CAUTION Installation of the transient protection terminal block does not provide transient protection unless the transmitter case is properly grounded Do not run signal wiring in conduit or open trays with power wiring, or near heavy electrical equipment. Do not connect the powered signal wiring to the test terminals.
  • Page 14 Quick Start Guide February 2019 Figure 4-3: Grounding A. Trim shield and insulate B. Insulate shield C. Terminate cable shield drain wire to earth ground D. Internal ground location E. External ground location Grounding for transient terminal block Ground termination is provided on the outside of the electronics housing and inside the terminal compartment.
  • Page 15: Verify Transmitter Configuration Using A Field Communicator

    Verify the configuration using any HART capable configuration tool or LOI - option code M4. Configuration instructions for a Field Communicator and LOI are included in this step. See Rosemount 2088 Reference Manual configuration instructions using AMS Device Manager. ™ A Rosemount 2088 DD must be installed on the Field Communicator to verify configuration.
  • Page 16 Quick Start Guide February 2019 Figure 5-2: Device Dashboard A check (✓) indicates the basic configuration parameters. At minimum, these parameters should be verified as part of the configuration and startup procedure. Table 5-1: Traditional Interface Fast Key Function Fast Key sequence ✓...
  • Page 17 February 2019 Quick Start Guide Table 5-1: Traditional Interface Fast Key (continued) Function Fast Key sequence Percent Range 1, 1, 2 Poll Address 1, 4, 3, 3, 1 ✓ Range Values 1, 3, 3 Rerange 1, 2, 3, 1 Scaled D/A Trim (4–20 mA) 1, 2, 3, 2, 2 Self Test (Transmitter) 1, 2, 1, 1...
  • Page 18 Quick Start Guide February 2019 Table 5-2: Device Dashboard Fast Keys (continued) Function Fast Key Sequence Field Revision Rev 3 Rev 5 Rev 7 HART Revision HART 5 HART 5 HART 7 Burst Mode 2, 2, 4, 1 2, 2, 5, 3 2, 2, 5, 3 Custom Display 2, 2, 3...
  • Page 19 February 2019 Quick Start Guide LOI button functionality is shown on the bottom corners of the display. See Table 5-3 Figure 5-4 for button operation and menu information. Figure 5-3: Internal and External LOI Buttons A. Internal buttons B. External buttons Note Figure 12 on page 15 to confirm external button functionality.
  • Page 20 Quick Start Guide February 2019 Figure 5-4: LOI Menu Assign PV HART Revision Switch HART Revision mode ® Task steps to switch the HART Revision mode from the generic menu. If the HART configuration tool is not capable of communicating with HART ™...
  • Page 21: Trim The Transmitter

    A zero trim can be performed using either a Field Communicator or configuration buttons. For instructions using AMS Device Manager,see the Rosemount 2088 Reference Manual. CAUTION It is not recommended to zero an absolute transmitter.
  • Page 22 Quick Start Guide February 2019 Table 6-1: Zero Trim Fast Keys Analog zero (Set 4 mA) Digital zero Fast Key 3, 4, 2 3, 4, 1, 3 sequence Trimming with configuration buttons A zero trim is to be performed using one of the three possible sets of external configuration buttons located under the top tag.
  • Page 23 February 2019 Quick Start Guide 2. Press and hold the zero button for two seconds to perform an analog zero trim. Perform trim with digital zero (option DZ) Procedure 1. Set the transmitter pressure. 2. Press and hold the zero button for two seconds to perform a digital zero trim.
  • Page 24: Safety Instrumented Systems (Sis) Installation

    Quick Start Guide February 2019 Safety Instrumented Systems (SIS) installation For safety certified installations, refer to Rosemount 2090 Manual Supplement for installation procedure and system requirements. ™ Rosemount 2088, 2090F, and 2090P Pressure Transmitter Quick Start Guide...
  • Page 25: Product Certifications

    A copy of the EU Declaration of Conformity can be found at the end of the Quick Start Guide. The most recent revision of the EU Declaration of Conformity can be found at Emerson.com/Rosemount. Ordinary Location Certification As standard, the transmitter has been examined and tested to determine that...
  • Page 26 Quick Start Guide February 2019 157-92, CSA Std C22.2 No. 213-M1987, ANSI- ISA-12.27.01-2003 Markings: Explosionproof for Class I, Division 1, Groups B, C and D; Class II, Groups E, F, and G; Class III; Intrinsically Safe Class I, Division 1 when connected in accordance with Rosemount drawing 02088-1024, Temperature Code T3C;...
  • Page 27 February 2019 Quick Start Guide Table 8-1: Input Parameters (continued) Power P 0.9 W Capacitance C 0.012 µF Special Conditions for Safe Use(X): 1. The apparatus is not capable of withstanding the 500 V insulation test required by EN60079-11. This must be taken into account when installing the apparatus.
  • Page 28 Quick Start Guide February 2019 8.1.3 International K7 IECEx Flameproof Certificate: IECEx KEM 06.0021X Standards: IEC60079-0:2011, IEC60079-1:2014,IEC60079-26:2014 Markings: Ex db IIC T6…T4 Ga/Gb, T6(–60 °C ≤T ≤ +70 °C), T4/T5(–60 °C ≤ T ≤ +80 °C) Special Conditions for Safe Use(X): 1.
  • Page 29 Special Conditions for Safe Use(X): 1. When fitted with a transient suppression terminal block, the Rosemount 2088 is incapable of passing the 500 V isolation test. This must be taken into account during installation. 2. The enclosure may be made of aluminum alloy and given a protective polyurethane paint finish;...
  • Page 30 Quick Start Guide February 2019 8.1.4 China E3 China Flameproof Certificate: GYJ15.1506X Standards: GB3836.1-2010, GB3836.2-2010 Markings: Ex d IIC T6/T4 Gb, T6(–20 °C ≤ T ≤ +40 °C), T4(–20 °C ≤ T ≤ +80 °C) Special Conditions for Safe Use (X): The ambient temperature is as follows: Temperature class –20 °C ≤...
  • Page 31 February 2019 Quick Start Guide Special Conditions for Safe Use(X): 1. The enclosure may contain light metal, attention should be taken to avoid ignition hazard due to impact or friction when used in Zone 0. 2. When transient protection board is chosen (option code T1), this apparatus is not capable of withstanding the 500 V r.m.s insulation test required by Clause 6.3.12 of GB3836.4-2010.
  • Page 32 Quick Start Guide February 2019 ATEX Flameproof and Increased Safety Certificate: FM13ATEX0076X Standards: EN60079-0:2012, EN60079-1:2007, EN60079-7:2007 Markings: Ex II 2 G Ex de IIC Gb Table 8-4: Conduit Plug Thread Sizes Thread Identification mark M20 x 1.5–6g 1/2-14 NPT 1/2 NPT G1/2A G1/2 Table 8-5: Thread Adapter Thread Sizes...
  • Page 33 A copy of the EU Declaration of Conformity can be found at the end of the Quick Start Guide. The most recent revision of the EU Declaration of Conformity can be found at Emerson.com/Rosemount. Ordinary Location Certification As standard, the transmitter has been examined and tested to determine that...
  • Page 34 Quick Start Guide February 2019 Markings: Explosionproof for Class I, Division 1, Groups B, C and D; Class II, Groups E, F, and G; Class III; Intrinsically Safe Class I, Division 1 when connected in accordance with Rosemount drawing 02088-1024, Temperature Code T3C; Ex ia; Class I Division 2 Groups A, B, C and D;...
  • Page 35 February 2019 Quick Start Guide Special Conditions for Safe Use(X): 1. The apparatus is not capable of withstanding the 500 V insulation test required by EN60079-11. This must be taken into account when installing the apparatus. 2. The enclosure may be made of aluminum alloy and given a protective polyurethane paint finish;...
  • Page 36 Special Conditions for Safe Use(X): 1. When fitted with a transient suppression terminal block, the Rosemount 2088 is incapable of passing the 500 V isolation test. This must be taken into account during installation. 2. The enclosure may be made of aluminum alloy and given a protective polyurethane paint finish;...
  • Page 37 Quick Start Guide Special Conditions for Safe Use(X): 1. When fitted with a transient suppression terminal block, the Rosemount 2088 is incapable of passing the 500 V isolation test. This must be taken into account during installation. NK IECEx Dust Certificate: IECEx BAS12.0073X...
  • Page 38 Special Conditions for Safe Use(X): 1. When fitted with a transient suppression terminal block, the Rosemount 2088 is incapable of passing the 500 V isolation test. This must be taken into account when installing the equipment. 2. The enclosure may be made of aluminum alloy and given a protective polyurethane paint finish;...
  • Page 39 February 2019 Quick Start Guide Temperature class –20 °C ≤ T ≤ 80 °C –20 °C ≤ T ≤ 40 °C 1. The earth connection facility on the enclosure should be connected reliably. 2. During installation in hazardous location, cable glands, conduits, and blanking plugs, certified by state-appointed inspection bodies with Ex d IIC type of protection, should be used.
  • Page 40 Quick Start Guide February 2019 Special Condition for Safe Use(X): 1. When transient protection board is chosen (option code T1), this apparatus is not capable of withstanding the 500 V r.m.s insulation test required by Clause 6.3.12 of GB3836.4-2010. 8.2.6 Korea EP Korea Flameproof Certificate: 13-KB4BO-0020X Markings:...
  • Page 41 February 2019 Quick Start Guide Combination of E2 and I2 Combination of E5 and I5 Combination of C6, ED, and I1 Combination of E7, I7, NK, and N7 Combination of K5 and C6 Combination of EM and IM Combination of ED, I1, K5 8.2.10 Conduit Plugs and Adapters IECEx Flameproof and Increased Safety Certificate Certificate: IECEx FMG 13.0032X...
  • Page 42 Quick Start Guide February 2019 1/2–14 NPT 1/2–14 NPT G1/2 G1/2 Special Conditions for Safe Use(X): 1. When the thread adapter or blanking plug is used with an enclosure in type of protection increased safety “e” the entry thread shall be suitably sealed in order to maintain the ingress protection rating (IP) of the enclosure.
  • Page 43 February 2019 Quick Start Guide Humidity Vibration Enclosure SLL Lloyds Register (LR) Type Approval Certificate: 11/60002 Application: Environmental categories ENV1, ENV2, ENV3, and ENV5 Quick Start Guide...
  • Page 44: Rosemount ™ 2088 And 2090 Declaration Of

    Quick Start Guide February 2019 ™ Rosemount 2088 and 2090 Declaration of Conformity EU Declaration of Conformity No: RMD 1010 Rev. N Rosemount, Inc. 8200 Market Boulevard Chanhassen, MN 55317-9685 declare under our sole responsibility that the product, Rosemount Pressure Transmitters 3051P, 2051G, 2088, and 2090 manufactured by, Rosemount, Inc.
  • Page 45 February 2019 Quick Start Guide EU Declaration of Conformity No: RMD 1010 Rev. N EMC Directive (2014/30/EU) Harmonized Standards: EN 61326-1:2013, EN 61326-2-3:2013 RoHS Directive (2011/65/EU) Model 2090F Pressure Transmitter Harmonized Standard: EN 50581:2012 ATEX Directive (2014/34/EU) BAS00ATEX1166X - Intrinsic Safety Certificate Equipment Group II Category 1 G Ex ia IIC T4 Ga Harmonized Standards:...
  • Page 46 Quick Start Guide February 2019 EU Declaration of Conformity No: RMD 1010 Rev. N ATEX Notified Bodies DEKRA (KEMA) [Notified Body Number: 0344] Utrechtseweg 310, 6812 AR Arnhem P.O. Box 5185, 6802 ED Arnhem The Netherlands Postbank 6794687 SGS FIMCO OY [Notified Body Number: 0598] P.O.
  • Page 47: China Rohs

    February 2019 Quick Start Guide China RoHS Quick Start Guide...
  • Page 48 The Emerson logo is a Facebook.com/Rosemount trademark and service mark of Emerson Electric Youtube.com/user/ Co. Rosemount is mark of one of the Emerson RosemountMeasurement family of companies. All other marks are the Google.com/+RosemountMeasurement property of their respective owners.

This manual is also suitable for:

Rosemount 2090fRosemount 2090p

Table of Contents