Figure E-4:
The transmitter, core processor, and sensor are all mounted separately. The 4-wire connection between
the transmitter and core processor must be field wired. The 9-wire connection between the core processor
and the sensor must be field wired. Power supply and I/O must be field wired to the transmitter. This
configuration is sometimes called double-hop.
A.
B.
C.
D.
E.
F.
Configuration and Use Manual
Remote core processor with remote sensor installation
A
B
Junction box
Sensor
Transmitter
Field-wired 4-wire connection
Core processor
Field-wired 9-wire connection
Transmitter components and installation wiring
C
D
E
F
249