5. Remove evaporator.
6. The installation is in the reverse order of the removal.
The Evaporator Installation Guide
1. Pack certain SW-100 compressor oil into the refrigerant circuit when installing a new evaporator.
Refill: (approximate)
15ml {15 cc, }
Check Evaporator
1. Remove evaporator.
2. Remove the evaporator core from the evaporator.
3. Check for crack, damage or oil leakage.
•
Replace the evaporator core if any of the above-mentioned fault occurs.
4. Check the fin for bending.
•
Flat it with a flat head screwdriver if it is bent.
Check Heater
1. Remove the heater.
2. Remove heating core from the heater.
3. Check for crack, damage or refrigerant leakage.
•
Replace the heating core if any of the above-mentioned faults occurs.
4. Check the fin for bending
•
Flat it with a flat head screwdriver if it is bent.
5. Check heater inlet hose and outlet hose for bend or damange.
•
Repair the hose if necessary.
309