(b) Inspect the combination meter connectors.
1
Inspect continuity
Disconnect the connector from the combination meter assembly
Inspect continuity between terminals
Standard:
Tester connection
B7 - ground
B8 - ground
2
Inspect voltage
Disconnect the connector from the combination meter assembly
Turn the ignition switch ON
Inspect voltage between terminals
Standard:
Tester connection
B4 - ground
Result and solution:
Normal
Replace the combination meter assembly
Abnormal
Repair or replace the harness or connector
176
Condition
Normal condition
Normal condition
Condition
Turn the ignition switch ON
Standard condition
Continuity
Continuity
Standard condition
10 – 14V