Geely CK Series 2007 Workshop Manual page 173

Table of Contents

Advertisement

II. CHARGING SYSTEM INSPECTION
1. CHECK BATTERY WORKING VOLTAGE
(a) After having driven the vehicle and in the case that 20 minutes have not passed after having stopped the
engine, turn the ignition switch ON and turn on the electrical system (headlight, blower motor) for 60
seconds to remove the surface charge.
(b) Turn the ignition switch OFF and
turn off the electrical systems. Then
measure the battery voltage
between the negative and positive
terminals of the battery.
Standard voltage: 12.5-12.9V at
20°C
HINT:
If the voltage is less than specification, charge the battery.
2. CHECK BATTERY TERMINALS, FUSE BOX AND FUSE
(a) Check that the battery terminals are not loose or corroded.
(b) Check if fuse box and fuse for continuity.
166

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ck mr479q 2007Ck mr479qa 2007Ck mr481q 2007

Table of Contents