Geely CK Series 2007 Workshop Manual page 197

Table of Contents

Advertisement

Analog Meter
Tachometer (r/min)
800
1000
2000
3000
4000
5000
6000
4. INSPECT FUEL LEVEL GAUGE
(1) Inspect resistance
When the fuel level gauge indicates no fuel, inspect the resistance between terminal A-12 and B-7 on the
combination meter connector.
Standard:
Standard indication
Warning point
1/2F
NOTICE:
Connector should be disconnected when measured.
5. INSPECT WATER TEMPERATURE GAUGE
(1) Inspect resistance
When the water temperature is indicated in the red area, inspect the resistance between terminal B-5 and
B-7 on the combination meter connector.
190
E
F
handy tachometer (r/min)
740—860
900—1100
1850—2150
2800—3200
3800—4200
4800—5200
5750—6250
Resistance (Ω)
104—116
90—100
29—35
1 — 5