Switcher Error Responses

When the switcher receives a valid SIS command, it executes the command and sends
a response to the host device. If the unit is unable to execute the command because the
command is invalid or it contains invalid parameters, the unit returns an error response to
the host. The error response codes are:
E01 — Invalid input channel number (too large)
E10 — Invalid command
E11 — Invalid preset number
E12 — Invalid output number (too large)
E13 — Invalid value (out of range)
E14 — Illegal command for this configuration
E17 — Timeout (caused only by direct write of global presets)
E21 — Invalid room number
E24 — Privilege violation (Ethernet only. Personnel logged in as users attempting

Using the Command and Response Tables

The command and response table begins on
letters are acceptable in the command field. Symbols, defined starting below and used
throughout the table, represent variables in the command and response fields. Command
and response examples are shown throughout the table. The ASCII to Hex conversion table
below is for use with the command and response table.
Space
operations requiring administrator privileges. Users have access to all view and read
commands [other than the administrator password], and can create ties and
presets, and mute and unmute the output.)
ASCII to Hex Conversion Table