Hot Plug and HDCP Events
X@
HplgO
*
X!
HdcpI
*
X@
HdcpO
*
Effect Select
X1(]
SwefO1*
Logo Event
X@
LogoE
*
X@
LogoE
*0
Take Event
]
Tke
]
Bsy1
]
Bsy0
Video Mute Event
X@
]
Vmt
*1
X@
]
Vmt
*2
X@
]
Vmt
*0
Video Freeze Event
X@
]
Frz
*1
X@
]
Frz
*0
Switcher Error Responses
When the switcher receives an SIS command and determines that it is valid, it performs the
command and sends a response to the host device. If the switcher is unable to perform
the command because the command is invalid or contains invalid parameters, the switcher
returns an error response to the host. The error response codes are:
E01 — Invalid input number
•
E10 — Invalid command
•
E11 — Invalid preset number
•
E12 — Invalid port or output number
•
E13 — Invalid parameter
•
•
E14 — Invalid for this configuration
NOTE: If the unit does not support or recognize the entered commands, no response is
issued.
X6(]
Broadcast upon detection of a Hot Plug event on the HDMI
outputs.
X4$]
Broadcast upon detection of a change in the HDCP status of
X!
input
.
X4$]
Broadcast upon detection of a change in the HDCP status of
X@
output
.
Broadcast upon selection of a new effect (for example: dissolve,
cut, wipe, video key, and PIP).
X8)]
Broadcast when a Logo is turned on for output
]
Broadcast when a Logo is turned off for output
Broadcast upon a Take event.
Broadcast upon the start of a Take effect.
Broadcast upon the completion of a Take effect.
Broadcast when video is muted on output
Broadcast when video and sync are muted on output
Broadcast when video is unmuted on output
Broadcast when video is frozen on output
Broadcast when video is unfrozen on output
ISS 608 and ISS 612 Seamless Switchers • SIS Configuration and Control
X@
.
X@
X@
.
X@
E17 — Invalid command for signal type
•
E22 — Busy
•
E24 — Privilege violation
•
E25 — Device not present
•
E26 — Maximum number of connections exceeded
•
•
E28 — Bad Filename / File not Found
X@
.
X@
.
X@
.
.
.
38