Appendix 13
The following table lists the added and enhanced functions in the Ethernet-equipped module.
: Available (No version restriction), : Not available
Added and enhanced function
Turning off the LED with the ERRCLEAR instruction
'State of receive buffer' (Un\G1900030)
• Automatic detection of connected devices
• Communication setting reflection
• Sensor parameter read/write
IP address change function
Redundant system function
Remote head module redundant system
File transfer function (FTP client)
High-speed write mode (File transfer function (FTP server))
Accessing to another station via the port 1 and port 2 using SLMP communications
Simple CPU communication function
Communications by network number/station number
MODBUS/TCP slave function
Simple CPU communication function for MELSEC iQ-F series
*1 'Receive buffer full detection signal' (Un\G21056) can be used when the network type is set to "Q Compatible Ethernet".
*2 Refer to the following.
iQ Sensor Solution Reference Manual
*3 There are restrictions on the CPU module to be used. For details, refer to the following.
MELSEC iQ-R CPU Module User's Manual (Application)
*4 Only the following models can be used. The supporting firmware version differs depending on the model.
Process CPU: "04" or later
SIL2 Process CPU: There are no restrictions on the version.
*5 Only the programmable controller CPU can be used. For the R00CPU, R01CPU, and R02CPU, there are no restrictions on the version.
*6 Only the following models can be used. The supporting firmware version differs depending on the model.
R00CPU, R01CPU, R02CPU: There are no restrictions on the version.
Programmable controller CPU (except for R00CPU, R01CPU, and R02CPU): "22" or later
Process CPU: "13" or later
*7 Only the following models can be used. The supporting firmware version differs depending on the model.
R00CPU, R01CPU, R02CPU: "05" or later
Programmable controller CPUs other than the above: "35" or later
*8 Only the following models can be used. The supporting firmware version differs depending on the model.
R00CPU, R01CPU, R02CPU: "08" or later
Programmable controller CPUs other than the above: "40" or later
APPX
406
Appendix 13 Added and Enhanced Functions
Added and Enhanced Functions
*1
*3
Firmware version
RJ71EN71
RnENCPU
(network part)
"05" or later
"05" or later
"10" or later
"10" or later
"12" or later
"12" or later
"18" or later
"35" or later
"35" or later
"35" or later
"35" or later
"35" or later
"35" or later
CPU module
(built-in Ethernet
port part)
*2
*4
*6
*5
"23" or later
*7
*8
*8