Mitsubishi Electric MELSEC iQ-RJ71EN71 User Manual page 401

Ethernet
Hide thumbs Also See for MELSEC iQ-RJ71EN71:
Table of Contents

Advertisement

■When the instruction completed with an error (timeout error at sending)
ECPRTCL instruction
Completion device
Completion device + 1
Ethernet-equipped module
External device
■When the instruction completed with an error (timeout error of waiting time to receive)
ECPRTCL instruction
Completion device
Completion device + 1
Ethernet-equipped module
External device
*1 When the receive packet (expected packet) verification does not match before the reception wait time, or when other device existence
cannot be checked within the destination alive check time (time calculated from destination alive check start interval timer value,
destination alive check interval timer value, and destination alive check resend count).
For details on errors that occur when the communication completed abnormally, refer to the error code stored
in the buffer memory.
( Page 310 List of Error Codes)
Waiting time
t: TCP ULP timer
to send
Send packet
The packet cannot be
sent or no response is
received from the
external device.
Waiting time
to send
Send packet
Send packet
Appendix 10 Operation Image and Data Structure of Predefined Protocol
An error has occurred.
The device turns on
upon abnormal end.
Discarded
Receive data
t: waiting time to receive or the time
specified by the destination alive check timer
Receive data
Receive data
The receive data did not
match the receive packet
(expected packet).
An error has
occurred.
The device
turns on upon
abnormal end.
*1
APPX