Download  Print this page

Mitsubishi Electric MELSEC iQ-RJ71EN71 User Manual Page 274

Ethernet.
Hide thumbs
   
1
2
3
4
5
6
7
8
9
10
Table of Contents
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416

Advertisement

■Combination System
This system combines the IP address calculation system and the table conversion system.
Select this system when accessing other stations with the same network number, accessing other stations in other networks
or Ethernet with different network number, or relaying from other networks to the Ethernet network system.
The set target Ethernet-equipped module can be installed either at a communication request source station, communication
relay station, or communication request destination station.
Conversion processing of the combination system is as below.
• When a communication request message (command frame) to access other station is received, the communication request
message is sent to the next station obtained by the table conversion system at first.
• If the IP address of the external device cannot be retrieved by the table conversion system, the IP address is retrieved by
the IP address calculation system to send the communication request message.
• The response message (response) to the communication request message is returned based on the return IP address and
data in the conversion table, or the stored data.
The relationship between the conversion method and the definition of the Ethernet-equipped module mounted station is as
follows.
: Can be set, : Cannot be set
Conversion method
Automatic Response System
IP Address Calculation
System
Table Conversion System
Combination System
*1 For the external device that completed the communication, the station can be a communication request source station or a relay sending
station.
Subnet Mask Pattern
Specify the mask value based on the guidelines given below. This pattern is used in a logical sum with the own station IP
address when calculating the IP address of the external device using the IP address calculation system.
When setting the subnet mask, specify the target settings of the IP address class, network address, and subnet address so
that all bits are "1" in the mask pattern.
Specify the mask pattern with a decimal/hexadecimal value obtained by dividing the 32-bit mask value into 8-bit segments.
When the subnet mask is not specified, the mask pattern setting is not necessary. The following mask value is used as the
mask pattern according to the own station IP Address class.
Class
Class A
Class B
Class C
Conversion Settings
The conversion setting is required to obtain the IP address from the network number and station number using the table
conversion system.
If the own station is an Ethernet-equipped module and the next station to which the communication request/response
message is passed to access other station is also an Ethernet-equipped module, specify the network number, station number,
and IP address of the Ethernet-equipped module of the next station.
2 PARAMETER SETTINGS
2.3 Application Settings
Ethernet-equipped module mounted station definition
Communication
Communication relay station
request source station
Relay receiving station
*1
Relay sending station
*1
Mask value used
FF.00.00.00H
FF.FF.00.00H
FF.FF.FF.00H
Communication
request destination
station

Advertisement

Table of Contents

   Also See for Mitsubishi Electric MELSEC iQ-RJ71EN71

Comments to this Manuals

Symbols: 0
Latest comments: