Registration Of Communication Destination - Mitsubishi Electric MELSEC iQ-RJ71EN71 User Manual

Ethernet
Hide thumbs Also See for MELSEC iQ-RJ71EN71:
Table of Contents

Advertisement

Registration of communication destination

Set the devices for both transmission source and transmission destination. Up to 64 devices can be registered.
■Module type list
The following table shows the communication devices and specifications applicable to each module.
Module type
*1
MELSEC iQ-R (built-in Ethernet)
MELSEC iQ-R (Ethernet module)
MELSEC iQ-F (built-in Ethernet)
*2
MELSEC-Q (built-in Ethernet)
MELSEC-Q (Ethernet module)
MELSEC-L (built-in Ethernet)
MELSEC-L (Ethernet module)
OMRON (CS/CJ series)
KEYENCE (KV series)
Panasonic (FP2SH series)
Panasonic (FP7 series)
YASKAWA MP3000 series
YASKAWA MP2000 series
Yokogawa FA-M3 series
SLMP-compatible device (QnA-
compatible 3E frame)
MODBUS/TCP-compatible device
*1 The model of the connection destination. When the "target PLC No." is specified, the CPU module that can configure a multiple CPU
system (the RnCPU, RnENCPU, RnPCPU, or RnSFCPU) can be specified as the communication destination.
*2 The model of the connection destination. When the "target PLC No." is specified, the CPU module that can configure a multiple CPU
system (the QnUDE(H)CPU, QnUDVCPU, or QnUDPVCPU) can be specified as the communication destination. For the multiple CPU
system of the MELSEC-Q series, refer to the following.
 QCPU User's Manual (Multiple CPU System)
*3 When the RnENCPU is used for the connection to the Ethernet port of the CPU part
*4 When the RnENCPU is used for the connection to the Ethernet port of the network part
Communication destination
*3
RnCPU, RnENCPU
, RnPCPU, RnSFCPU, RnPSFCPU
*4
RnENCPU
, RJ71EN71
FX5U CPU module, FX5UC CPU module
Built-in Ethernet port QCPU
QJ71E71-100
Built-in Ethernet port LCPU
LJ71E71-100
Supported model for SYSMAC CS/CJ series
Supported model for KV series
Supported model for FP2 series
Supported model for FP7 series
Supported model for MP3000 series
Supported model for MP2000 series
Supported model for FA-M3 series
• SLMP-compatible device (No serial number)
• MC protocol 3E frame-compatible device
MODBUS/TCP-compatible device
1.15 Simple CPU Communication Function (RJ71EN71, RnENCPU (Network Part))
Communication specification
MELSOFT connection (protocol:
UDP)
MELSOFT connection (protocol:
TCP)
MELSOFT connection (protocol:
UDP)
FINS
SLMP (MC protocol QnA-compatible
3E frame)
MEWTOCOL
MEWTOCOL7
Extended MEMOBUS
Personal computer link
SLMP (MC protocol QnA-compatible
3E frame)
• Read (0401H)
• Write (1401H)
MODBUS/TCP
1 FUNCTIONS
195
1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents