■Case of the RJ71EN71 or RnENCPU (network part)
The IP address value is written into the IP address storage area (flash ROM). The write and clear operations are performed
with the buffer memory.
Buffer memory
Un\G11700
IP address
Un\G11701
Un\G11702
Subnet mask
Un\G11703
Un\G11704
Default gateway
Un\G11705
Un\G11706
Network No.
Un\G11707
Station No.
Transient transmission
Un\G11708
group No.
IP address storage area
(flash ROM)
IP address
Subnet mask pattern
Write execution
Default gateway
(Un\G11709.0 ON)
IP address
Network No.
Station No.
Transient transmission
group No.