Download  Print this page

Mitsubishi Electric MELSEC iQ-RJ71EN71 User Manual Page 233

Ethernet.
Hide thumbs
   
1
2
3
4
5
6
7
8
9
10
Table of Contents
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416

Advertisement

Communications using the fixed buffer
■Receive processing by the standby system
If data is sent to the standby system Ethernet-equipped module, data reception processing will not be performed because the
module reads and discards the received data.
■Receive processing with interrupt program
If system switching occurs before execution with the interrupt program, and the control system is switched to the standby
system, the interrupt factor will not be transferred to the other system. The interrupt factor will be retained on the own system.
Therefore, if system switching occurs again and the own system becomes the control system, the interrupt program will be
executed by the retained interrupt factor.
■When data is sent from an external device
The data sending method will differ according to whether the communication method and the control system IP address are
usable.
Communication method
Fixed Buffer (Procedure Exist)
Fixed Buffer (No Procedure)
When performing the resend processing when system switching occurs, pay attention to the following.
• When communicating while synchronizing send and receive, system switching may occur in the middle of
communication, and systems may be switched in a state where send and receive are not synchronized
together. When system switching occurs, out of safety considerations, restart communication after
initialization of synchronization.
• When using dedicated instructions, note that the completion of the execution of a write instruction needs to
be executed is difficult to judge, and that the same instruction needs to be executed again. Note, however,
that the same instruction may be executed twice.
Availability of control system
IP address
Not Use
Use
Send method
When system switching occurs because of a response timeout to the
Ethernet-equipped module, send by changing the connection destination to
the other system.
When system switching occurs because of a response timeout to the
Ethernet-equipped module, open a new control system.
Also, check whether the Ethernet-equipped module is alive from the external
device side.
System switching timing cannot be ascertained because of no setting for the
response timeout. Send data to the Ethernet-equipped modules of both
systems.
1.17 Redundant System Function
1
1 FUNCTIONS
231

Advertisement

Table of Contents

   Also See for Mitsubishi Electric MELSEC iQ-RJ71EN71

Comments to this Manuals

Symbols: 0
Latest comments: