Rev 3.0B Feb.08
Example: ATDT1234567 would go to ID "12" on the Modbus
list and use the associated IP as the destination.
•
n=0 : Disabled
•
n=1 : Enabled
MVLEN=n
Modbus Variant ID Length: Length of the RTU ID in a
modbus‐variant protocol, in bytes.
•
n=1 : This parameter is used to define the length of the
RTU ID in Modbus‐like protocol data packets.
•
n=2 : This parameter is used when the when the MD is set
to hex 63.
MVMSK=hh
Modbus Variant ID Mask: Byte hex mask to use when
extracting the ID. Specify which bits in the ID field to use. This
parameter is used when the when the Mode Default (MD) is
set to hex 63.
•
hh=hex value
·
00 ‐ no mask, all 8 bits (default)
·
0F ‐ only the low order 4 bits
MVOFF=n
Modbus (variable mode) Offset: Indicates the offset in the data
of where the Modbus ID starts.
•
n=0 ‐ 255
MVOPT=n
Modbus Variant Option: Sets various behavioral options when
dealing with a Modbus‐variant protocol. This parameter is
used when the when MD is set to hex 63. Cannot be configured
in AceManager.
•
n=0 : No special action (Default).
•
n=1 : Skip leading zeroes in Modbus packets.
MVTYP=n
Modbus Variant Type: The data‐type of the RTU ID in a
modbus‐variant protocol. This parameter is used to define the
data‐type of the RTU ID in Modbus‐like protocol data packets.
This parameter is used when MD is set to 63.
•
n=0 : Binary (Default)
•
n=1 : ASCII Hex
•
n=2 : ASCII Decimal
Configuration Commands
121