Raven iDEN
Note: This mode is not available
through the remote AT telnet
server. You will need to connect
to the Raven with it connected
directly to your computer.
112
\APASSTHRU
Sets the modem operation to pass through mode. This mode
will pass any characters received on the port Ethernet directly
to the internal hardware module and output any characters
from the internal hardware module out the port Ethernet. This
allows direct access/configuration of the hardware module.
Once this mode is entered, the unit must be physically reset to
return to normal operation. This command is not available in
AceManager.
Note: It may take up to 30 seconds for the hardware module to
respond after CONNECT is output.
*CSX1=n
PassThru Echo : Echo data to the host.
•
n=0 : Data will be passed to the host.
•
n=1 : PASSTHRU mode will echo all host received data
and will not pass the data to the modem while the modem
is not asserting DCD.
Note: If the modem is asserting DCD, data will be passed from the
host to the modem as it normally is when *CSX1=0.
*PTINIT=string
Any AT Command string to be passed to the OEM module
before entering PASSTHRU mode, e.g. AT&S1V1, etc.
•
string=AT command(s)
*PTREFRESH=n
Number of minutes of inactivity in PASSTHRU mode to
resend the *PTINIT string to the hardware module.
•
n=0 : Disabled
n=1‐255 minutes
•
*RESETPERIOD=n
In PASSTHRU mode, modem will be reset after this period if
no data has been sent or received. Value is in hours.
•
n=0 : Disabled
•
n=1‐255 hours
20070914