Mounting of cables
1. Unscrew the cover and
remove the two blind
plugs.
When changing the cables on a LINAK actuator, it is important that this is done carefully, in order to
protect the plugs and pins. Before the new cable is mounted, we recommend that the socket is greased
with vaseline, to keep the high IP protection and ensure an easy mounting. Please be sure that the plug is
in the right location and fully pressed in before the cable lid is mounted.
Remove the tinned cable end when the cable end is mechanically connected, the tinned end is only to be
used when a soldered connection is made.
Please note that if the cables are mounted and dismounted more than 3 times the plugs can be damaged.
Therefore, we recommend that such cables are discarded and replaced.
Also note that the cables should not be used for carrying the actuator.
We recommend to take some precaution and design the wire connection in a way, where the cable end is
kept inside a closed, protected area to guarantee the high IP protection.
2. Plug in the power
cable and/or the
signal cable.
Page 12 of 80
3. Slide the cover onto
the actuator.
The torque of the
cover screw is
approx. 3.5 ± 0.3 Nm
TORX 25IP
Need help?