Actuator with Parallel
I/O specifications:
Input/Output
Green
Yellow
Violet
White
Current cut-offs should not be used as stop function! This might damage the actuator. Current
cut-offs should only be used in emergencies!
Current cut-off limits are not proportional with the load curves of the actuator. This means that the
current cut-offs cannot be used as load indicator.
There are tolerances on the spindle, nut, gear wheels etc. and these tolerances will have an
influence on the current consumption for the specific actuator.
Specification
Endstop signal out
Endstop signal in
Parallel communication:
Violet cords must be connected together
Signal GND:
White cords must be connected together
Comments
Output voltage min. V
Source current max. 100mA
Endstop signals are NOT potential free.
Endstop signals can be configured with
BusLink software according to any
position needed
Standby power consumption:
12V, 60mA
24V, 45mA
No feedback available during parallel
drive
For correct wiring of power GND and
Signal GND see page 42
Page 48 of 80