Safety instructions

1.1

Designated use

The measuring device described in these Operating Instructions is to be used only for measuring the
flow of liquids in closed pipes, e.g.:
• Ultra clean water with low conductivity
• Water, wastewater, etc.
As well as measuring the volume flow, the measuring system also always measures the sound
velocity of the fluid. The sound velocity can be used to distinguish different fluids or as a measure
of fluid quality.
The manufacturer accepts no liability for damage resulting from incorrect use or other than
designated use.
1.2

Installation, commissioning and operation

Note the following points:
• Installation, connection to the electricity supply, commissioning and maintenance of the device
must be carried out by trained, qualified specialists authorized to perform such work by the facil-
ity's owner-operator. The specialist must have read and understood these Operating Instructions
and must follow the instructions they contain.
• The device must be operated by persons authorized and trained by the plant operator.
Strict compliance with the instructions in the Operating Instructions is mandatory.
• Endress+Hauser will be happy to assist in clarifying the chemical resistance properties of parts
wetted by special fluids, including fluids used for cleaning.
• If welding work is performed on the piping system, do not ground the welding appliance through
the Prosonic flowmeter.
• The installer must ensure that the measuring system is correctly wired in accordance with the
wiring diagrams. The transmitter must be grounded, unless the power supply is galvanically
isolated.
• Invariably, local regulations governing the opening and repair of electrical devices apply.
1.3

Operational safety

Note the following points:
• Measuring systems for use in hazardous environments are accompanied by separate "Ex docu-
mentation", which is an integral part of these Operating Instructions. Strict compliance with the
installation instructions and connection data as listed in the supplementary "Ex" documentation
is mandatory. The symbol on the front of the Ex documentation indicates the approval and the
certification body (0 Europe, 2 USA, 1 Canada).
• The measuring device complies with the general safety requirements in accordance with
EN 61010, the EMC requirements of EN 61326/A1, and NAMUR Recommendation NE 21.
• The manufacturer reserves the right to modify technical data without prior notice. Your
Endress+Hauser distributor will supply you with current information and updates to these
Operating Instructions.