Nameplate Of The Prosonic Flow W/P Sensors; Nameplate Of The Prosonic Flow U Sensors - Endress+Hauser Proline Prosonic Flow 90 Operating Instructions Manual

Ultrasonic flow measuring system
Hide thumbs Also See for Proline Prosonic Flow 90:
Table of Contents

Advertisement

2 Identification
10
2.1.2

Nameplate of the Prosonic Flow W/P sensors

1
2
3
4
5
8
7
Fig. 2:
Nameplate specifications for the "Prosonic Flow W" sensors (example)
1
Ordering code / serial number: See the specifications on the order confirmation for the meanings of the
individual letters and digits.
2
Sensor type
3
Range of nominal diameters: DN 100...4000
4
Max. fluid temperature range:
5
Reserved for information on special products
6
Degree of protection
7
Ambient temperature range
8
Data on explosion protection
Refer to the specific additional Ex documentation for detailed information.
Please do not hesitate to contact your Endress
2.1.3

Nameplate of the Prosonic Flow U sensors

ENDRESS+HAUSER
PROSONIC FLOW U
2
U-CL-2F-L-A
Type:
4
TM:
-20°C (-4°F) ... +80°C (+175°F)
6
T amb.:
-20°C (-4°F) ... +60°C (+140°F)
7
FM
APPROVED
Fig. 3:
Nameplate specifications for the "Prosonic Flow U" sensors (example)
1
Ordering code / serial number: See the specifications on the order confirmation for the meanings of the
individual letters and digits.
2
Sensor type
3
Range of nominal diameters: DN 15...100
4
Max. fluid temperature range:
5
Degree of protection
6
Ambient temperature range:
7
Data on explosion protection
Refer to the specific additional Ex documentation for detailed information.
Please do not hesitate to contact your Endress
ENDRESS+HAUSER
PROSONIC FLOW W
XXXXX-XXXXXXXXXXXX
Order Code:
12345678901 RY
Ser.No.:
W-CL-1F-L-B
Type:
DN100 - DN4000
-20°C (-4°F) ... +80°C (+175°F)
OPEN
6
IP67
FM
APPROVED
II3G
EEx nL IIC/IIB T6-T1
CL.I, Div.2, GP . ABCD
Dust-Ignitionproof for
CL.II, Div.1, GP . EFG, CL.III
For Installation refer to
Tamb/Tumg:-20°C..+60°C
control dwg. of transmitter
+
+
20 °C (
4 °F) ...
80 °C (
175 °F)
+
Hauser sales office if you have any questions.
1
Order Code:
Ser.No.:
3
DN15 - DN100
CL.I, Div.2, GP. ABCD
CL.I, Zone 2 IIC T6-T1
For Installation refer to control dwg. of transmitter
20 °C (
4 °F) ...
+
80 °C (
+
175 °F)
20 °C (
4 °F) ... v60 °C (
+
140 °F)
+
Hauser sales office if you have any questions.
Proline Prosonic Flow 90
XA0..D/
i
2001
06/a3/....
CLOSE
NEMA
TYPE 4X
93UA1-XXXXXXXXXXXX
12345678901
i
CH 1
IP54
5
Endress+Hauser
A0001101
A0001102

Hide quick links: