Mechanical Construction - Endress+Hauser Proline Prosonic Flow 90 Operating Instructions Manual

Ultrasonic flow measuring system
Hide thumbs Also See for Proline Prosonic Flow 90:
Table of Contents

Advertisement

Proline Prosonic Flow 90
Design / dimensions
Weight
Materials
Endress+Hauser
10.1.8

Mechanical construction

see Page 104 ff.
Transmitter housing:
• Wall-mount housing: 6.0 kg
Measuring sensors:
• Flowrate measuring sensors P (clamp-on) incl. mounting rail and tensioning bands: 2.8 kg
• Flowrate measuring sensors W (clamp-on) incl. mounting rail and tensioning bands: 2.8 kg
• Flowrate measuring sensors U (clamp-on): 1 kg
• Flowrate measuring sensors W (Insertion): 4.5 kg
Transmitter housing 90 (wall-mount housing):
powder-coated die-cast aluminum
Standard designations of the materials (measuring sensors W/P/U)
Standard sensor cable
– Cable connector (nickled brass)
– Cable sheath
Sensor housing W/P (clamp-on)
Sensor holder W/P (clamp-on)
Sensor housing U (clamp-on)
Frame end-piece for U sensor
– Cast steel
Welding parts for W sensors
(Insertion version)
Sensor contact surface
Tensioning bands
High temperature sensor cable
– Cable connector (stainless steel)
– Cable sheath
U sensor fixation bar
– Cast aluminum
DIN 17660
2.0401
PVC
DIN 17440
1.4301
1.4308
Plastic
1.4308
1.4301
Chemical resistant plastic
1.4301
1.4301
PTFE
DIN EN 573-3
EN AW-6063
10 Technical data
UNS
C38500
PVC
AISI
304
CF-8
CF-8
304
304
304
PTFE
ASTM B3221
AA 6063
101

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents