Omron NX-series User Manual page 256

Safety network controller communication control unit built-in function
Hide thumbs Also See for NX-series:
Table of Contents

Advertisement

Appendices
Variable name
_EIP2_TDLinkStartCmd
Meaning
CIP Communications2 Tag Data Link Communi-
cations Start Switch
Function
Change this variable to TRUE to start tag data links for CIP communications 2.
It automatically changes back to FALSE after tag data link operation starts.
Note Do not force this switch to change to FALSE from the user program or from the Sysmac Studio.
Data type
BOOL
R/W access
RW
Variable name
_EIP_TDLinkStopCmd
Meaning
Tag Data Link Communications Stop Switch
Function
Change this variable to TRUE to stop tag data links for CIP communications 1.
It will automatically changes back to FALSE after tag data link operation stops.
Note Do not force this switch to change to FALSE from the user program or from the Sysmac Studio.
Data type
BOOL
R/W access
RW
Variable name
_EIP1_TDLinkStopCmd
Meaning
CIP Communications1 Tag Data Link Communi-
cations Stop Switch
Function
Change this variable to TRUE to stop tag data links for CIP communications 1.
It automatically changes back to FALSE after tag data link operation stops.
Note Do not force this switch to change to FALSE from the user program or from the Sysmac Studio.
Data type
BOOL
R/W access
RW
Variable name
_EIP2_TDLinkStopCmd
Meaning
CIP Communications2 Tag Data Link Communi-
cations Stop Switch
Function
Change this variable to TRUE to stop tag data links for CIP communications 2.
It automatically changes back to FALSE after tag data link operation stops.
Note Do not force this switch to change to FALSE from the user program or from the Sysmac Studio.
Data type
BOOL
R/W access
RW
A - 82
It changes to FALSE automatically.
Retained
Not retained.
It changes to FALSE automatically.
Retained
Not retained.
It changes to FALSE automatically.
Retain
Not retained.
It changes to FALSE automatically.
Retained
Not retained.
NX-series Communication Control Unit Built-in Function User's Manual (Z396)
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.
Global/local
Global
Range of values
TRUE or FALSE
Network Publish
Published.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nx-csg series