Variable name
Meaning
_EIP1_TDLinkCfgErr
CIP Communica-
tions1 Tag Data Link
Setting Error
_EIP2_TDLinkCfgErr
CIP Communica-
tions2 Tag Data Link
Setting Error
_EIP_TDLinkOpnErr
Tag Data Link Con-
nection Failed
_EIP1_TDLinkOp-
CIP Communica-
nErr
tions1 Tag Data Link
Connection Failed
_EIP2_TDLinkOp-
CIP Communica-
nErr
tions2 Tag Data Link
Connection Failed
_EIP_TDLinkErr
Tag Data Link Com-
munications Error
NX-series Communication Control Unit Built-in Function User's Manual (Z396)
Function
Indicates that the tag data link settings
for CIP communications 1 are incorrect.
Or, a read operation failed.
TRUE: Setting incorrect or read failed.
FALSE: Normal
Indicates that the tag data link settings
for CIP communications 2 are incorrect.
Or, a read operation failed.
TRUE: Setting incorrect or read failed.
FALSE: Normal
Indicates that establishing a tag data link
connection for CIP communications 1
failed.
TRUE: Establishing a tag data link con-
nection failed due to one of the following
causes.
The information registered for a target
node in the tag data link parameters is
different from the actual node informa-
tion.
There was no response from the re-
mote node.
FALSE: Other than the above.
Indicates that establishing a tag data link
connection for CIP communications 1
failed.
TRUE: Establishing a tag data link con-
nection failed due to one of the following
causes.
The information registered for a target
node in the tag data link parameters is
different from the actual node informa-
tion.
There was no response from the re-
mote node.
FALSE: Other than the above.
Indicates that establishing a tag data link
connection for CIP communications 2
failed.
TRUE: Establishing a tag data link con-
nection failed due to one of the following
causes.
The information registered for a target
node in the tag data link parameters is
different from the actual node informa-
tion.
There was no response from the re-
mote node.
FALSE: Other than the above.
Indicates that a timeout occurred in a tag
data link connection for CIP communica-
tions 1.
TRUE: A timeout occurred.
FALSE: Other than the above.
Appendices
Range of
Data type
values
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
Reference
page A - 71
page A - 71
A
page A - 71
page A - 71
page A - 72
page A - 72
A - 39