Safety network controller communication control unit built-in function
Hide thumbs Also See for NX-series:
Table of Contents

Advertisement

• _EIP2_EstbTargetSta (CIP Communications2 Normal Target Node Information)
• _EIP2_TargetPLCErr (CIP Communications2 Target PLC Error Information)
• _EIP2_TargetNodeErr (CIP Communications2 Target Node Error Information)
l Functional Classification: EtherNet/IP Communications Switches
Variable name
Meaning
_EIP_TDLink-
Tag Data Link Com-
StartCmd
munications Start
Switch
_EIP1_TDLink-
CIP Communica-
StartCmd
tions1 Tag Data Link
Communications
Start Switch
_EIP2_TDLink-
CIP Communica-
StartCmd
tions2 Tag Data Link
Communications
Start Switch
_EIP_TDLink-
Tag Data Link Com-
StopCmd
munications Stop
Switch
_EIP1_TDLink-
CIP Communica-
StopCmd
tions1 Tag Data Link
Communications
Stop Switch
NX-series Communication Control Unit Built-in Function User's Manual (Z396)
Function
Change this variable to TRUE to start tag
data links for CIP communications 1.
It automatically changes back to FALSE
after tag data link operation starts.
Note Do not force this switch to
change to FALSE from the
Sysmac Studio or other means
before it automatically changes
to FALSE.
Change this variable to TRUE to start tag
data links for CIP communications 1.
It automatically changes back to FALSE
after tag data link operation starts.
Note Do not force this switch to
change to FALSE from the
Sysmac Studio or other means
before it automatically changes
to FALSE.
Change this variable to TRUE to start tag
data links for CIP communications 2.
It automatically changes back to FALSE
after tag data link operation starts.
Note Do not force this switch to
change to FALSE from the
Sysmac Studio or other means
before it automatically changes
to FALSE.
Change this variable to TRUE to stop tag
data links for CIP communications 1.
It will automatically changes back to
FALSE after tag data link operation
stops.
Note Do not force this switch to
change to FALSE from the
Sysmac Studio or other means
before it automatically changes
to FALSE.
Change this variable to TRUE to stop tag
data links for CIP communications 1.
It automatically changes back to FALSE
after tag data link operation stops.
Note Do not force this switch to
change to FALSE from the
Sysmac Studio or other means
before it automatically changes
to FALSE.
Appendices
Range of
Data type
values
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
BOOL
TRUE or
FALSE
Reference
page A - 81
A
page A - 81
page A - 82
page A - 82
page A - 82
A - 51