10.Attach spacer bar by inserting reference sensor pin into the REF hole. Insert Index
Number pin into appropriate Index Number hole.
Note
There are two threaded holes in each enclosure housing, labeled "D" and "E". Use the
hole that matches the sensor size.
Figure B-32
11.Fully tighten and torque all stand off strap retainer nuts to approximately 2.25 - 2.8
newton/meters (20-25 in/lbs). Lock stand offs in place with second nut.
12.Proceed to installing Sensors - Dual enclosure (Page 125).
Figure B-33
B.4.3.4

Sensors - Single enclosure

Installation procedure
Note
In the following procedure use the coupling compound that is supplied with your sensor.
FSS200 clamp-on sensors
Installation Manual, 08/2017, A5E36255466-AC
Spacer bar setup