7. Lower the fixed reference sensor into the enclosure housing with one hand and then, with
the other hand, insert the threaded end of the screw pin through the REF slot and into the
sensor. Make sure sensor does not make contact with the pipe at this time.
Figure B-35
Note
Be careful not to catch or compromise the yellow insulating tape while inserting the
sensor. The insulating tape is used to insulate metal components of the sensor for
cathodically protected pipe.
8. Mate the sensor to the pipe.
Note
Do not smear couplant while mating sensor to pipe.
9. Position clamp plate screw assembly into notch and slide over sensor.
Figure B-36
Note
Each enclosure will have one sensor from each opposing sensor set; i.e. The enclosure
housing at path 1 will have the "A" sensor from set 1 mounted in the upstream location
and the "B" sensor from set 2 will be mounted in the downstream location. The enclosure
housing for path 2 will have the "A" sensor from set 2 mounted in the upstream location
and the "B" sensor from set 1 will be mounted in the downstream location.
FSS200 clamp-on sensors
Installation Manual, 08/2017, A5E36255466-AC
Reference hole (REF)
Index numbers
Spacer bar
Sensor clamp plate screw and locking nut
Additional Installation Instructions