Additional Installation Instructions
B.4 Hi Precision mount
10.Tighten clamp plate screw to secure sensor and torque screw to 1.7 newton/meters (15
in/lbs). Ensure plate screw aligns with detent in top of sensor. Secure with locking nut.
Figure B-42
11.Thread second unterminated sensor cable through enclosure housing grommet and
terminate cable. (Refer to previous cable instructions.)
12.Install second sensor as described above.
13.Install enclosure housing covers using a flat blade screwdriver and cover screws.
Figure B-43
14.Proceed to Sensor wiring (Page 48) to connect the sensor cables to the transmitter.
15.Complete the flowmeter make-up process and verify that the sensor installation is
complete before continuing to the final step. Adjustment of the index pins may be
required.
16.Installation of the sensors is now complete.
17.Return to transmitter and finalize programming.
128
Sensor detent
Installed Hi Precision mount dual enclosure
FSS200 clamp-on sensors
Installation Manual, 08/2017, A5E36255466-AC