B.3 Magnetic mounting
8. Prepare the surface of the pipe. De-grease the surface, if necessary, and remove any
grit, corrosion, rust, loose paint, etc. Use abrasive material provided to provide a clean
contact surface for the sensors.
9. Mounting mode applications - see figures below.
Note
Do not mount frames over frost.
Do not mount frames on the seam of pipe.
Figure B-12
B.3.3

Reflect mount

B.3.3.1

Magnetic mounting frame procedures

Reflect mount
The Magnetic mounting frames establish the axial alignment of the sensors and allow the
removal and replacement of either sensor while preserving their exact mounting location.
1. Use the Wizard setup procedure to program the transmitter for the sensors that were
selected.
2. After receiving the spacing number index from the transmitter, make a note of the number
displayed.