Technical specifications

14.1

General specifications

General specifications
Order number
Dimensions
Weight
Supply voltage (V
Input current AC
Line voltage frequency
Transient voltage interruption
Power consumption
Power loss / heat emission
Current delivery (DC)
Noise emission
Degree of protection
Dust protection
Safety
Protection class
Safety regulations
Electromagnetic compatibility (EMC)
Radiated interference
Noise immunity: Mains borne
disturbance variables on supply lines
Noise immunity on signal lines
Immunity to discharge of static
electricity
SIMATIC IPC647C
Operating Instructions, 12/2010, A5E02669337-02
6AG4112-1...(for details, refer to the ordering documentation)
430.4 x 88.1 x 444.4 (W x H x D in mm). Detailed dimensional
specifications can be found in the
device (Page
Min. 10 kg, max. 14 kg
)
100 to 240 VAC (-15 %, 10 %), varying voltage; with transient
N
power failure backup in accordance with NAMUR:
Continuous current up to 6 A (up to 30 A for 5 ms at startup)
50 to 60 Hz (min. 47 Hz to max. 63 Hz, sinusoidal)
Min. 20 ms at 93 V
(max. 10 events per hour; recovery time at least 1 s)
Approx. 210 W maximum at 80% efficiency
210 W = 210 J/s = 0,20 BTU/s
+5 V/30 A +3.3 V/28 A, max. accumulated power 160 W
+12 V/15 A -12 V/0.5 A -5 V/0.5 A +5 Vaux/2 A
Accumulated power of all voltages max. 170 W
< 45 dB(A) at 25 °C to DIN EN ISO 7779
ODDs not in operation
IP41 at the front and IP20 at the rear to IEC 60529
With closed front panel
Filter class G2 EN 779, 99% of particles > 0.5 mm are filtered
Protection class I according to IEC 61140
EN 61000-6-3, FCC class A
EN 61000-3-2 class D and EN 61000-3-3
± 2 kV (to IEC 61000-4-4; Burst)
± 1 kV (to IEC 61000-4-5; Surge symm.)
± 2 kV (to IEC 61000-4-5; Surge asymm.)
± 1 kV (to IEC 61000-4-4; Burst; Length < 30 m)
± 2 kV (to IEC 61000-4-4; Burst; Length > 30 m)
± 2 kV (to IEC 61000-4-5; Length > 30 m)
± 6 kV contact discharge (to IEC 61000-4-2)
± 8 kV air discharge (according to IEC 61000-4-2)
1 43) section.
3
IEC 60950-1
EN 60950-1
UL 60950-1
CSA C22.2 No 60950-1-07
14
D imensional drawing of the
8
135