Siemens Simatic IPC647C Operating Instructions Manual page 149

Hide thumbs Also See for Simatic IPC647C:
Table of Contents

Advertisement

Component / interface
PROFIBUS/MPI
PROFINET
USB 2.0
Ethernet (two
interfaces)
Electrical isolation within the safety extra-low voltage circuit (SELV)
1
Optional product feature
2
Depends on the CPU type
3
Depending on the selected device configuration,
4
a floppy disk drive cannot be ordered using the configurator.
AMT and teaming cannot be used simultaneously on the Ethernet interface.
5
SIMATIC IPC647C
Operating Instructions, 12/2010, A5E02669337-02
Description
SIMATIC S7
2
communication
interface
Communication
2
interface for
PROFINET
IO applications and
SIMATIC installations
Universal Serial Bus
10BaseT/100Base-
TX/1000Base-TX
Ethernet 1:
Intel® 82577LM Gigabit
Network Connection
(Hanksville)
Ethernet 2:
Intel® 82574L Gigabit
Network Connection
Parameters
Electrically isolated
1
- 12 Mbps
10/100 Mbps, electrically isolated
CP 1616 compatible 3-port interface
7 high-current (500 mA) USB 2.0 ports, of those:
2 on the front
4 on the back
1 inside
10/100/1000 Mbps, electrically isolated
Wake on LAN, remote boot
AMT-capable
, teaming-capable
5
supports jumbo frames up to 4088 bytes
teaming-capable
supports jumbo frames up to 9014 bytes
Detailed descriptions
16.1 Motherboard
compatible to CP5611
1
1
149