Hitachi GVX-CC64GxBX series User Manual page 97

Gigabit fibre channel adapter
Table of Contents

Advertisement

[Example 2]
Before you replace SFP transceiver, execute isolate command. If command succeed, port
status will change to Isolate(C ) and Transceiver replacement to replaceable. This means you
can hot-replace SFP transceiver.
Figure Sample of executing hfcmgr –sfp command (Isolate)
#./hfcmgr -sfp hfcldd1
Do you execute it? (y/n) > y
Succeeded.
#./hfcmgr –sfp
Device:hfcldd1
SFP Part Number
Serial Number : PES437S
Date Code
Transceiver Replacement : replaceable
>
[Example 3]
After you replace SFP transceiver, execute recover command. If command succeed, port status
will change from Isolate(C ) to Linkdown or Linkup. This means now you can connect the
adapter port through replaced SFP transceiver.
Figure Sample of executing hfcmgr –sfp command (recover)
#./hfcmgr -sfp hfcldd1 clear
Do you execute it? (y/n) > y
Succeeded.
#./hfcmgr -sfp
Device:hfcldd1
SFP Part Number
Serial Number : PES437S
Date Code
Transceiver Replacement : not replaceable
>
WWPN:5000087000572642
: FTLF8524P2BNV-HD
: 090124
WWPN:5000087000572642
: FTLF8524P2BNV-HD
: 090124
76
Status:Isolate(C)
Status:LinkUp

Advertisement

Table of Contents
loading