Table 34 - Fault Codes, Fault Text, and Fault Help Strings for Drive Units
Fault
Code
Fault Text
5
Phase U to Gnd
6
Phase V to Gnd
7
Phase W to Gnd
8
Phase UV Short
9
Phase UW Short
10
Phase VW Short
11
Ground Fault
12
Stall Trip
13
Switched Power
14
Under Power Trip
15
Sensor Short
16
Output Short
17
Fault 17
18
Heatsink Temp
19
HW Over Current
20
SW OverCurrent
21
Aux Power Loss
22
Internal Comm
23
Drive Comm Loss
24
Power Loss
25
Under Voltage
26
Over Voltage
27
MCB EEPROM
28
Param Sync
29
Drive EEPROM
30
Hardware Fault
31
Fan RMP
32
Power Unit
33
Drive I/O Brd
34
Restart Retries
35
Drive Aux In Flt
36
Fault 36
37
Drv Param Reset
38
Fault 38
39
Fault 39
40
Unknown Fault
Rockwell Automation Publication 290E-UM001B-EN-P - June 2012
Help Text
A Phase U to Ground fault detected between drive and motor.
A Phase V to Ground fault detected between drive and motor.
A Phase W to Ground fault detected between drive and motor.
Excessive current detected between phases U and V.
Excessive current detected between phases U and W.
Excessive current detected between phases V and W.
A current path to earth ground at one or more output terminals.
The drive is unable to accelerate the motor.
Indicates the loss of switched control power.
Not available in units with Integrated Power Supply
Indicates the internal power supply is below its working level.
Available in units with Integrated Power Supply only.
Flags a miswired hardware input point.
Flags a miswired hardware output point.
The Heatsink temperature exceeds a predefined value.
The drive output current has exceeded the hardware limit.
Programmed parameter 83 (SW Current Trip) has been exceeded.
Auxiliary Power was lost or dipped below the minimum threshold.
Not available in units with Integrated Power Supply.
Communication with the internal Power Flex drive has been lost.
The RS485 port on the internal Power Flex stopped communicating.
Drive DC Bus Voltage remained below 85% of nominal bus voltage.
DC Bus Voltage fell below the minimum value.
DC Bus Voltage exceeded the maximum value.
This is a major fault which renders the ArmorStart inoperable.
The drive and Main Control Board EEPROMS are not in sync.
The drive EEPROM checksum checks have failed.
This is a major fault which renders the unit inoperable
The internal cooling fan is not running properly.
A major failure has been detected in the drive power section.
A failure has been detected in the drive control and I/O section.
Automatic fault reset and run retries exceeded.
The drive auxiliary input interlock is open inside the ArmorStart.
Internal Drive Parameters (Parameters > 100) have been defaulted.
CIP Information
Appendix B