BrakeMode
This parameter determines the source
brake control mode.
0 = NoBrakeControl
1 = AboveFrequency
2 = AboveCurrent
BrakeFreqThresh
This parameter determines the frequency
above which the source brake is released.
BrakeCurrThresh
This parameter determines the motor
current above which the source brake
is released.
For parameter 90 and 91 the value of the threshold can be set beyond the
IMPORTANT
operational maximum limit of the product, or at a level which may cause
multiple transitions during operation. Threshold values near the operational
levels should be avoided.
Rockwell Automation Publication 290E-UM001B-EN-P - June 2012
Bulletin 290E/291E/294E Programmable Parameters
Parameter Number
Related Parameters
Access Rule
Data Type
Group
Units
Minimum Value
Maximum Value
Default Value
Parameter Number
Related Parameters
Access Rule
Data Type
Group
Units
Minimum Value
Maximum Value
Default Value
Parameter Number
Related Parameters
Access Rule
Data Type
Group
Units
Minimum Value
Maximum Value
Default Value
Chapter 4
89
GET/SET
UINT
Advanced Config.
0
2
1
90
GET/SET
UINT
Advanced Config.
x.x Hz
0.0
999.9
0.0
91
GET/SET
UINT
Advanced Config.
x.xx Amps
0.0
8.0
0.0